CRISTAL 9 - LIFE 9 - CRISTAL PLUS 9 - ICON PLUS 9 - STEEL 9
16
• Press “menu” to confirm.
• Modify the % with the + - keys.
• Press “menu” to confirm and “esc” to exit
i - Smoke Fan rpm
To change the parameter act as follows:
• Press the “menu” button.
• Scroll to “Settings” using the arrows
• Press “menu” to confirm.
• Scroll to “Smoke Fan rpm” using the arrows.
• Press “menu” to confirm.
• Modify the % with the + - keys.
• Press “menu” to confirm and “esc” to exit
j - Components Test
To activate the “Components Test” function (only when the boiler is switched off) act as follows:
• Press the “menu” button.
• Scroll to “Settings” using the arrows
• Press “menu” to confirm.
• Scroll to “Components Test” using the arrows.
• Press “menu” to confirm.
• Select the test to be performed with the + - keys
• Press “menu” to confirm and “esc” to exit
k - “Chimney Sweep Function"
To activate the “Chimney Sweep Function” function act as follows:
• Press the “menu” button.
• Scroll to “Settings” using the arrows
• Press “menu” to confirm.
• Scroll to the “Chimney Sweep Function” function using the arrows.
• Press “menu” to confirm.
• Select “On” with the + - keys (Off by default)
• Press “menu” to confirm and “esc” to exit
l - Technical Menu
To access the technical menu one must contact an assistance centre as one needs a password to enter.
8.5
INFO MENU
• Product Type
• Firmware Version
• Software info
• Total hrs.
• Ignition N.
• Rpm Smoke Fan
• Smoke Temp.
• Air Fan Voltage
• Screw Loading
• Fire
8.6
IGNITION OF THE STOVE
We remind you that the first ignition must be carried out by a specialized and authorixed technician who will check that all is
installed in compliance with current regulations and checks the efficiency.
• If inside the combustion chamber there are booklets, manuals, etc..., remove them.
• Check if the door is correctly closed.
• Check if the stove is correctly inserted in the electric socket.
• Before switching the stove on, assure you the burning pot is clean.
• To start the stove, keep the P1 button pressed until the ON sign and a flashing flame to its side appear. The ignition resistance
pre-heating starts. After some seconds the feed screw loads pellets and the resistance pre-heating continues. When the tem-
Содержание CRISTAL 9
Страница 35: ...NOTE ...