23

LUCE   -  ELLE  -  ARCO 

Used batteries contain metals which are harmful for the environment; they must therefore be disposed of 

separately in the special containers.

Fig. 28 - Remote control

LEGEND

Fig. 28

Button 1

Increase the desired temperature (5÷35 °C)

Button 2

Decrease the desired temperature (35÷5 °C)

Button 3

On / off

Button 4

Menu

Button 5 

Decrease the power level from 5 to 1

Button 6 

Increase the power level from 1 to 5 

12  SAFETY DEVICES AND ALARMS

The product is supplied with the following safety devices

12.1  PRESSURE SWITCH

•  It controls pressure in the fume duct. It blocks the pellet feed screw in the following instances:

•  clogged exhaust

•  Significant negative (wind)

•  clogged fume passages

•  open pellet loading tank

•  open fire door or worn/broken gaskets.

•  see SMOKE RPM VARIATION User Manual

12.2  SMOKE TEMPERATURE PROBE

Detects the temperature of the smoke, thereby enabling start-up or stopping the product when the temperature drops below the 

preset value.

12.3  CONTACT THERMOSTAT IN THE FUEL HOPPER

If the temperature exceeds the preset safety level, it immediately shuts down boiler operation.

12.4  ELECTRICAL SAFETY

The product is protected against sudden current surges by a main fuse in the power supply panel on the rear part of the product. 

Other fuses that protect the electronic boards are found on the latter.

12.5  SMOKE FAN

If the fan stops, the electronic board promptly shuts off the pellets supply and an alarm message is displayed.

Содержание ARCO 7 T1 BI-FLUX

Страница 1: ...EN USER MANUAL Pellet Stove 2023CADELsrl Allrightsreserved Tuttiidirittiriservati new ARCO 7 T1 ARCO 7 T1 BI FLUX ARCO 9 T2 ARCO 9 T2 BI FLUX ELLE PLUS 9 T2 LUCE PLUS 9 T2...

Страница 2: ...ONXSETTINGSMENU A PAG 13 19 8 17 PELLETS RECIPE SEE SECTION H SETTINGS MENU A PAG 13 20 8 18 SMOKE RPM VARIATION SEE SECTION I SETTINGS MENU A PAG 13 20 8 19 CHIMNEY SWEEP FUNCTION FOR MAINTENANCE TEC...

Страница 3: ...includingthosereferringtonationalandEuropeanstandards mustbeobservedwheninstallingtheappliance In Italy for the installation of systems with a biomass below 35KW refer to the Ministerial Decree 37 08...

Страница 4: ...these operating conditions increase the risk of premature wear of the product especially those parts exposed to the direct heat of the fire e g combustion chamber theoriginalconditionofwhichcanunderg...

Страница 5: ...protector made of in combustiblematerial steel glass etc thatalsoprotectsthefrontpartfromanyfallingburnt particles during cleaning The electrical cable must not get in touch with the fume exhaust pip...

Страница 6: ...ly check and empty the inspectionable parts of the smoke duct e g Tee fitting caps Have the smoke outlet system periodically checked and cleaned The product is not a cooking appliance Always keep the...

Страница 7: ...Damage caused during transportation or relocation All parts that develop faults due to negligence or improper use incorrect maintenance installation that does not comply with the manufacturer s instru...

Страница 8: ...e sole party responsible for demolishing and disposing of the product This must be performed in compliance with laws related to safety and environmental protection in force in his her country At the e...

Страница 9: ...2 Wastedisposal Thissymbol whichisusedontheproduct batteries accumulatorsoronthepackagingordocuments meansthatattheendofits useful life this product the batteries and the accumulators included must no...

Страница 10: ...com petent body APPLIANCE BAG POLYETHYLENE HD PE 2 SORTED waste collection PLASTIC Check the instructions of the com petent body APPLIANCE BAG BAG OF ACCESSORIES BUBBLEWRAP PROTECTIVE SHEET LABELS PO...

Страница 11: ...e chimney flue is efficient Switch on the stove at Power 5 for at least 2 hours in order to enable the materials which make up the boiler and the fireplace to adjust the inner springing stress After 2...

Страница 12: ...ingmenutoincrease 5 Decreasesettemperature programmingfunctions 6 Increasesettemperature programmingfunctions 7 Display 8 Time 9 Status 10 Temperature setbyuser 11 Instantpower 12 Ambienttemperature 1...

Страница 13: ...ith the keys select the language of interest IT EN DE FR ES NL PL DA SL Press menu to confirm and esc to exit b Cleaning To select Cleaning only when the boiler is switched off act as follows Press th...

Страница 14: ...ress menu to confirm Scroll to Easy Set using the arrows Press menu to confirm With the keys select Easy Set of interest SET1 SET2 SET3 SET4 Press menu to confirm and esc to exit h Pellet Recipe To ch...

Страница 15: ...pot is clean To start the stove keep the P1 button pressed until the ON sign and a flashing flame to its side appear The ignition resistance pre heatingstarts Aftersomesecondsthefeedscrewloadspellets...

Страница 16: ...ettled Afterablack outofmorethan10seconds thestoveenterstheduringshutdown Completedthisphase itstartsautomatically up with the different phases 8 10 ADJUSTMENTS MENU To access the adjustments menu act...

Страница 17: ...ngerperiod Theflamesetgoestotheminimumvalueautomaticallywhenthesettemperaturevalueisreached If only one notch appears the stove has a flame power equal to 1 If 5 notches appear the stove has a flame p...

Страница 18: ...ave any effect while OFF will switch it off In the boiler on and timer active condition press the OFF key and the boiler will switch off it will switch on automatically at the next time set on the tim...

Страница 19: ...13 Proper operation of a stove mainly depends on the flue it is connected to Once it is connected it is equally important to perform proper adjustment of combustion parameters The Easy Set feature ma...

Страница 20: ...ase with respect to the default setting 15 15 increase with respect to the default setting 8 18 SMOKE RPM VARIATION SEE SECTION I SETTINGS MENU A PAG 13 Changestobemadewiththesupportoftheauthorisedtec...

Страница 21: ...ctanAuthorized AssistanceService The main quality certifications for pellets currently available on the European market guarantee that the fuel complies with class A1 A2accordingtoISO17225 2 Thesecert...

Страница 22: ...ading system stops when the tank door is opened Before closing the lid make sure there are no pellets below the gasket Pellets deteriorate the gasket and eliminateitsairtightsealing vediFig 25 10 VENT...

Страница 23: ...haust Significant negative wind clogged fume passages open pellet loading tank open fire door or worn broken gaskets see SMOKE RPMVARIATION User Manual 12 2 SMOKE TEMPERATURE PROBE Detects the tempera...

Страница 24: ...E OF PROBLEM SOLUTION A01 The fire does not ignite Check whether the brazier is clean level of pellets in the hopper Check pellet level in the tank Check that the burning pot is correctly positioned i...

Страница 25: ...erationsmustbeplannedintimewithyourAutorizedTechnicalAssistanceService After a long ineffective time before turning on the stove check if there are obstructions in the fume exhaust If the stove had be...

Страница 26: ...example put on a wooden floor as the inner ash keeps the embers firing for a long time Only when the embers are off the ash coul be poured in the organic waste Pay attention if the flame becomes red...

Страница 27: ...s ceramic of the fire door is able to stand till 700 C but not to thermal shocks The probable cleaning with usual sale product for glass cleaning must be effected at cool glass in order to avoid explo...

Страница 28: ...tareessential for the correct operation of the product is provided below USER TECHNICIAN PARTS FREQUENCY 1 DAY 2 3 DAYS 7 DAYS 1YEAR UNDERTHE USER S RESPONSIBILITY Brazier X Ash compartment X Glass X...

Страница 29: ...en fire door or open pellet door Close fire door and pellet door and check that there are no pellet grains at the gasket level Clogged stove Fume chamber cleaning Auger blocked by a foreign object for...

Страница 30: ...d Faulty fume tempe rature probe Replace the fume probe Faulty mother board Replace the mother board Ash remains along the stove Faulty or out of order door gaskets Replace the gaskets Not sealed fume...

Страница 31: ...133 mg Nm3 Heat output Nominal heat output Pnom 8 5 kW Minimum heat output indicative Pmin 3 3 kW Useful efficiency NCV as received Useful efficiency at nominal heat output th nom 89 Useful efficiency...

Страница 32: ...Heat output Nominal heat output Pnom 7 4 kW Minimum heat output indicative Pmin 3 3 kW Useful efficiency NCV as received Useful efficiency at nominal heat output th nom 90 Useful efficiency at minimu...

Страница 33: ...NOTE...

Страница 34: ...NOTE...

Страница 35: ...NOTE...

Страница 36: ...www cadelsrl com www free point it www pegasoheating com CADEL srl 31025 S Lucia di Piave TV Via Martiri della Libert 74 Italy Tel 39 0438 1520200 Rev 00 2023...

Отзывы: