17
LUCE - ELLE - ARCO
Fig. 12 - Display
Fig. 13 - Display
Fig. 14 - Display
With function “1” or "2" or "3" or "4" or "5" the fan is forced to work at the selected output. (For example: by setting “3”, even if the
fan is set to heat output 5 it will work as if set to heat output “3”, etc.).
If the stove is set to maximum heat output 5 and the fans to minimum output 1, this may cause overheating
and the “THERMAL SAFETY” alarm to go off.
Comfort Mode -
In the air versions, it cannot be deactivated. At power 1 the fans are off.
In versions with ducting, the comfort mode allows you to automatically activate or deactivate all the fans at power 1.
If set in automatic (A), the comfort mode is active by default and disables, in addition to the room fan, also the ducting fans. To
reactivate them, simply set their adjustment other than automatic, e.g. 1,2,3,4,5.
Fire
- this function allows setting the flame power from a minimum of 1 to a maximum of 5. The power levels correspond to a diffe-
rent fuel consumption value: by setting 5 you can heat the room in less time, while by setting 1 you can keep the ambient tempera-
ture constant for a longer period. The flame set goes to the minimum value automatically when the set temperature value is reached.
If only one notch appears, the stove has a flame power equal to 1.
If 5 notches appear, the stove has a flame power equal to 5.
If the notches flash, automatic cleaning is under way.
Fig. 15 - Display
Fig. 16 - Power levels
8.11 PROGRAMMED MODE (TIMER) - MAIN MENU
Setting the current day and time is essential for the proper operation of the timer.
There are six TIMER programmes, for each one the user can decide the start-up and shutdown time as well as the day of the week
in which it is active.
When one or more programmes are active, the panel alternately displays the boiler status and TIMER “n” whereby “n” is the number
relating to the activated timer programmes, separated from each other with a dash
Example:
• TIMER 1 Timer programme 1 active.
• TIMER 1-4 Timer programmes 1 and 4 active.
• TIMER 1-2-3-4-5-6 Timer programmes all active.
EXAMPLE OF PROGRAMMING
With boiler on or off:
• access the MENU,
• scroll to TIMER with the <> arrows,
• press the “Menu” key
• the system proposes “P1” (Press the <> keys for the subsequent timers P2,P3, P4, P5, P6)
• to activate “P1” press the “Menu” key
• press + - and select “ON”
• confirm with the “Menu” key
At this point it will propose 00:00 as starting time, with key + - adjust the starting time and press the “menu” key to confirm.