LUCE - ELLE - ARCO
28
After removing the plugs from the power socket, open the fusebox cover with a screwdriver and replace the fuses if necessary (3.15
A delayed) - seek assistance from an authorised and qualified technician.
13.12 CHECKING THE INNER COMPONENTS
ATTENTION!
The internal electromechanical components must only be checked by qualified personnel
whose technical expertise includes combustion and electricity.
We recommend for this yearly maintenance to be carried out (with a scheduled service contract). This operation consists of a visual
and functional inspection of the internal components. A summary of the checks and/or maintenance operations that are essential
for the correct operation of the product is provided below.
USER/TECHNICIAN
PARTS/FREQUENCY
1 DAY
2-3 DAYS
7 DAYS
1 YEAR
UNDER THE USER'S RESPONSIBILITY
Brazier
X
Ash compartment **
X
Glass
X
BY THE QUALIFIED TECHNICIAN
Upper exchanger
X
Lower exchanger
X
Smoke duct
X
Gaskets
X
Door closure operation
X
** Emptying of the ash compartment depends on various factors (pellet type, stove power, stove use, type of installation...); the
exact emptying time will be suggested by experience.
14 IN CASE OF ANOMALY
14.1 PROBLEM SOLVING
Before of every Authorized Technician intervention, the same Technician has the duty to check if the parame-
ters of the mother board correspond to those of the table you own.
In case of doubts regarding the use of the stove, please contact ALWAYS the Authorized Technician on order to
avoi irreparable damages!