IDROSTUFE A PELLET
6
The chimney pot is important for the correct running of the heating appliance:
• We recommend using an anti-wind chimney pot, see
Fig. 4
.
• The hole width for fumes exhaust must be the double of the chimney flue width and fitted in a way that the fume exhaust is
assured also in case of wind.
• It should prevent the infiltration of rain, snow and animals.
• The outlet height in the atmosphere must be away from the reflux area caused by the roof structure or by obstacles laying
nearby (see
Fig. 2
).
3.7
CHIMNEY COMPONENTS
Fig. 5 - Chimney components
LEGEND
Fig. 5
1
Chimney pot
2
Fume outlet
3
Chimney flue
4
Termal insulation
5
External wall
6
Chimney union
7
Fume pipe
8
Heat generator
9
Inspection door
10
T-union with inspection plug
3.8
CHIMNEY FLUE CONNECTION
Your pellet stove works through a fume draught forced by a fan. It is obligatory to check that all pipes are realized in compliance
with the following regulation on material selection: EN 1856-1, EN 1856-2 e UNI/TS 11278. All must be effected by specialized
personnel or companies as provided by UNI 10683:2012.
• The connection between the appliance and the chimney flue should be short in order to favor the draught and to avoid con-
densation in the pipes.
• The fume conduit should be equivalent or longer than the outlet joint ones (Ø 80 mm).
• Some stove models are endowed with a lateral and/or back exhaust. Check that the unused exhaust is sealed with the plug
given with standard equipment.
Содержание AQUOS3 16
Страница 54: ...NOTE ...
Страница 55: ...NOTE ...