41
IDROSTUFE A PELLET
8.8
GASKET REPLACEMENT
In case of deterioration of fire door, hopper or fume chamber gaskets, it is necessary to replace them by an autorized technician in
order to guarantee the good running of the stove.
Use exclusively original spare parts.
9
IN CASE OF ANOMALY
9.1
PROBLEM SOLVING
Before of every Authorized Technician intervention, the same Technician has the duty to check if the parame-
ters of the mother board correspond to those of the table you own.
In case of doubts regarding the use of the stove, please contact ALWAYS the Authorized Technician on order to
avoi irreparable damages!
PROBLEM
CAUSE
SOLUTION
INTERVENTION
The control display
does not switch on
The stove is
without power
supply
Check if the plug is connected.
Burned protection
fuse in the electric
socket
Replace the protection fuses in the electric socket (3.15A-
250V).
Faulty control
display
Replace the control display.
Faulty flat cable
Replace the flat cable.
Faulty electronic
board
Replace the mother board.
Pellets do not
reach the combu-
stion chamber
Empty hopper
Full the hopper.
Open fire door or
open pellet door
Close fire door and pellet door and check that there are no
pellet grains at the gasket level.
Clogged stove
Fume chamber cleaning