Be sure to keep fireplace dampers closed when not in use . They provide 
an excellent escape route for heat, as well as humidity . 
On occasion, indoor moisture producing activities such as clothes drying, 
cooking, showers, etc ., may raise the humidity level higher than it should 
be, even though the humidifier is not operating . Telltale indications are 
condensation or frost on cold surfaces such as windows, doors, walls, 
etc . If such condensation persists for several hours, your home should be 
ventilated to dissipate the potentially damaging excess moisture .

ADDITIONAL INFORMATION

MAINTENANCE

Turn the control knob to the maximum RH setting . Make sure that the 
water saddle valve is open and that the humidifier is on . The indoor unit 
blower must be running for the humidifier to function . Once humidifier 
operation is verified, reduce the Humidifier Control setting to the 
recommended inside humidity, depending on the outside temperature . 

If using the automatic humidifier control model number 
KUAWC0101COR, DO NOT LEAVE IN TEST MODE AS HUMIDIFIER 
WILL NOT OPERATE. 

CHECK THE HUMIDIFIER OPERATION

 WARNING

ELECTRIC SHOCK HAZARD.

 Disconnect main electrical power 

to the humidifier at the circuit breaker and drain the water from 
unit before servicing. Hot surface inside.

NOTICE

•  Service should be performed by an HVAC technician.
•  Use only genuine replacement parts.

INSPECT HUMIDIFIER WHEN SERVICING

• Replace the canister annually and when prompted by the “Service” light
• Clean drain valve and fill valve screen annually
• Replace electrode wires every 3 years or more frequently as needed (see 

step 3 of 

CANISTER REPLACEMENT AND DRAIN VALVE SERVICE

)

• Inspect humidifier at approximately 500 hour intervals or several times 

during the humidification season .

SERVICE SHUTDOWN PROCEDURE

1 .  Press 

On/Off

 button to turn humidifier off (see 

FIGURE 2

) .

2 .  Allow humidifier to drain .
3 .  When the green 

Drain

 light (see 

FIGURE 2

) stops flashing, disconnect 

main electrical power to humidifier at the circuit breaker .

4 .  Allow the unit to cool .
5 .  Shut off water supply to unit . 

FIGURE 2 – Steam Humidifier

1

   On/Off  button 

and light

2

   Drain  light

3

   Front  panel

4

   Side  panel

5

   Service  light

3

4

1

2

5

CANISTER REPLACEMENT AND DRAIN VALVE SERVICE

Use only genuine replacement part number 8045HUM . 
1 .  Remove front panel (see 

FIGURE 2

) .

2 .  Pull three wires off posts on top of canister (two electrode wires and 

one water level probe wire, shown in 

FIGURE 3A

 and 

FIGURE 3B

) .

Содержание HUM STM3034 Series

Страница 1: ...READ AND SAVE THESE INSTRUCTIONS Model HUMCRSTM3134 HUMXXSTM3034 HUMXXSTM3134 Residential Steam Humidifier Owner s Manual Includes Safety Operating Instructions Residential Steam Humidifier...

Страница 2: ...until electrical power is disconnected Follow the shutdown procedure in this manual before performing service or maintenance procedures on any part of the system ELECTRICAL SHOCK HAZARD If the humidif...

Страница 3: ...and Canister 90 1522 Steam Outlet Drain Supply Water Drain Cup Drain Valve Canister Electrodes High Water Level Sensor Flow Control Orifice Inlet Fill Valve Overflow Fill Fill Cup Thank you for your...

Страница 4: ...s time the Steam light illuminates green If the humidifier cannot produce steam at the rated level after trying for 168 hours the Steam light illuminates yellow The humidifier continues to operate in...

Страница 5: ...ent level below 75 of the maximum operating current Humidifier continues to operate but at reduced capacity Solid Red Operational problem with humidifier Humidifier shuts down Occurs when unit detects...

Страница 6: ...HOCK HAZARD Disconnect main electrical power to the humidifier at the circuit breaker and drain the water from unit before servicing Hot surface inside NOTICE Service should be performed by an HVAC te...

Страница 7: ...w O ring O ring is provided with Model 8045HUM canister into slot in drain assembly Dampen O ring with water before inserting canister Do not use oil grease or any lubricant besides water 12 Make sure...

Страница 8: ...er relay One wire either one but not both must go through current sensing toroid see FIGURE 3A Electrode wires are interchangeable and can be placed on either of the two terminals FILL VALVE SERVICE 1...

Страница 9: ...Catalog No OM HUMCRSTM 02 10016625 B2210113B 02 23 2023 CAC BDP 7310 West Morris St Indianapolis IN 46231...

Отзывы: