- 12 -

- 13 -

3 .  Inspect the two electrode wires (see 

ELECTRODE WIRE REPLACEMENT

 

section for detailed instructions) . 

  Replace them if they are:

• Not tightly fitting
• Damaged
• Over 3 years old or age is unknown
• Have D shaped connectors (see 

FIGURE 4A

)

4 .  Loosen hose clamp at top of canister . Slide steam hose off top of canister 

(see 

FIGURE 5

) .

5 .  Slide canister up and out of drain assembly (see 

FIGURE 5

) . Discard old 

canister .

6 .  Remove O-ring from drain assembly using small screwdriver . Discard old 

O-ring .

7 .  With your finger, swirl the fluid/precipitate mixture in the bottom of the 

drain valve reservoir (see 

FIGURE 5

) .

8 .  Using a sponge or paper towels, soak up the water in the reservoir . If 

necessary, use a wet/dry vacuum to remove residue .

9 .  Clean the inside of the drain port (where coil projects out) by gently 

swabbing with a bent cotton swab or other soft implement .

10 .  Rinse the drain valve reservoir with clean water and vacuum as necessary .
11 .  Insert new O-ring (O-ring is provided with Model 8045HUM canister) 

into slot in drain assembly . Dampen O-ring with water before inserting 
canister . Do not use oil, grease, or any lubricant besides water .

12 .  Make sure strainer is inserted into bottom of new canister .
13 .  Insert new canister into drain assembly (see 

FIGURE 5

) .

14 .  Slip steam hose over top of canister and tighten hose lamp (see 

FIGURE 5

) .

15 .  Reconnect the electrode wires and water level probe wire to the posts 

on top of the canister (see 

FIGURE 3A

 and 

FIGURE 3B

) . Electrode wires 

are interchangeable and can be placed on either of the two electrode 
posts on top of the canister . 

Ensure connectors are fully seated.

J8

J10

CANISTER  ELECTRODES

POWER

RELAY

WATER LEVEL 

PROBE

ONE WIRE MUST GO THROUGH 

CURRENT-SENSING TOROID

ELECTRODE

POST

90-2352

FIGURE 3A –  

Two Circuit Boards

FIGURE 3B –  

One Circuit Board

STEAM

OUTLET

DRAIN

SUPPLY

WATER

DRAIN CUP

DRAIN VALVE

DRAIN ASSEMBLY

ELECTRODES

WATER LEVEL PROBE

FILL 

VALVE

OVERFLOW

FILL

STEAM HOSE

DISPERSION

TUBE IN DUCT 

TUBELETS

CANISTER

90-1522

FIGURE 5 – Fill & Drain 

System and Canister

90-2736

FIGURE 4A –  

“D” Shaped Connector

FIGURE 4B –  

“O” Shaped Connector

Содержание HUM STM3034 Series

Страница 1: ...READ AND SAVE THESE INSTRUCTIONS Model HUMCRSTM3134 HUMXXSTM3034 HUMXXSTM3134 Residential Steam Humidifier Owner s Manual Includes Safety Operating Instructions Residential Steam Humidifier...

Страница 2: ...until electrical power is disconnected Follow the shutdown procedure in this manual before performing service or maintenance procedures on any part of the system ELECTRICAL SHOCK HAZARD If the humidif...

Страница 3: ...and Canister 90 1522 Steam Outlet Drain Supply Water Drain Cup Drain Valve Canister Electrodes High Water Level Sensor Flow Control Orifice Inlet Fill Valve Overflow Fill Fill Cup Thank you for your...

Страница 4: ...s time the Steam light illuminates green If the humidifier cannot produce steam at the rated level after trying for 168 hours the Steam light illuminates yellow The humidifier continues to operate in...

Страница 5: ...ent level below 75 of the maximum operating current Humidifier continues to operate but at reduced capacity Solid Red Operational problem with humidifier Humidifier shuts down Occurs when unit detects...

Страница 6: ...HOCK HAZARD Disconnect main electrical power to the humidifier at the circuit breaker and drain the water from unit before servicing Hot surface inside NOTICE Service should be performed by an HVAC te...

Страница 7: ...w O ring O ring is provided with Model 8045HUM canister into slot in drain assembly Dampen O ring with water before inserting canister Do not use oil grease or any lubricant besides water 12 Make sure...

Страница 8: ...er relay One wire either one but not both must go through current sensing toroid see FIGURE 3A Electrode wires are interchangeable and can be placed on either of the two terminals FILL VALVE SERVICE 1...

Страница 9: ...Catalog No OM HUMCRSTM 02 10016625 B2210113B 02 23 2023 CAC BDP 7310 West Morris St Indianapolis IN 46231...

Отзывы: