19
Figure 11 : Model CVM Size 105
Table 10 : Minimum clearances to combustible materials
LOCATION
APPLICATION
UPFLOW
DOW NFLOW
HORIZONTAL
FURNA CE
Ø
5.08 cm (2")
5.08 c m (2")
SUPPLY PLENUM WITHIN 6 f t. OF FURNA CE
2.54 c m (1")
5.08 cm (2")
2.54 c m (1")
BA CK
FURNA CE
Ø
2.54 cm (1")
Ø
FURNA CE OR PLENUM
5.08 c m (2")
5.08 cm (2")
5.08 c m (2")
HORIZONTA L WA RM A IR DUCT WITHIN 6 f t. OF FURNA CE
5.08 c m (2")
5.08 cm (2")
7.62 c m (3")
BOTTOM
FURNA CE (COMBUSTIBLE FLOOR WITH SUB-BA SE † )
Ø
* Ø
** Ø
HORIZONTA LLY OR BELOW FLUE PIPE
10.16 cm (4")
10.16 c m (4")
10.16 cm (4")
V ERTICA LLY A BOV E FLUE PIPE
22.86 cm (9")
22.86 c m (9")
22.86 cm (9")
FRONT
FURNA CE
20.32 cm (8")
20.32 c m (8")
60.96 c m (24")
SIDES
TOP
FLUE PIPE
† When used with floor base model:
*
KLASB0601DET or **KLASB0701DET
Содержание CBMAAA060120
Страница 21: ...21 Figure 13 Wiring diagram CVM ...
Страница 22: ...22 Figure 14 Parts list CVMAAR036105 B50003 Rev D ...
Страница 24: ...24 Figure 15 Parts list CVMAAR060120 B50004 Rev F ...
Страница 48: ...23 Figure 13 Diagramme électrique CVM ...
Страница 49: ...24 Figure 14 Liste de pièces CVMAAR036105 B50003 Rev D ...
Страница 51: ...26 Figure 15 Liste de pièces CVMAAR060120 B50004 Rev F ...