18
Table 9 : Air Flow Data, Size 120
SW1- HEAT
DIP switch position
HEAT INPUT
(USGPH)
CFM avec SW3-ADJ
DIP switch position A
CFM with SW3-ADJ
DIP switch position B
CFM with SW3-ADJ
DIP switch position C
A (1=OFF, 2=OFF)
0.85
1450
1595
1305
B (1=ON, 2=OFF)
1.00
1700
1870
1530
C (1=OFF, 2=ON)
1.10
1850
2035
1665
D (1=ON, 2=ON)
SW2- COOL
DIP switch position
A/C size
(TON)
CFM with SW3-ADJ
DIP switch position A
CFM with SW3-ADJ
DIP switch position B
CFM with SW3-ADJ
DIP switch position C
A (1=OFF, 2=OFF)
5.0
1500
1725
1275
B (1=ON, 2=OFF)
4.0
1200
1380
1020
C (1=OFF, 2=ON)
3.5
1050
1205
890
D (1=ON, 2=ON)
3.0
900
1035
765
SW2- COOL
DIP switch position
A/C size
(TON)
CFM with SW3-ADJ
DIP switch position A
CFM with SW3-ADJ
DIP switch position B
CFM with SW3-ADJ
DIP switch position C
A (1=OFF, 2=OFF)
5.0
2000
2200
1800
B (1=ON, 2=OFF)
4.0
1600
1760
1440
C (1=OFF, 2=ON)
3.5
1400
1540
1260
D (1=ON, 2=ON)
3.0
1200
1320
1080
SW2- COOL
DIP switch position
A/C size
(TON)
CFM with SW3-ADJ
DIP switch position A
CFM with SW3-ADJ
DIP switch position B
CFM with SW3-ADJ
DIP switch position C
A (1=OFF, 2=OFF)
5.0
1600
1760
1440
B (1=ON, 2=OFF)
4.0
1280
1410
1150
C (1=OFF, 2=ON)
3.5
1120
1230
1010
D (1=ON, 2=ON)
3.0
960
1055
865
SW4- DELAY
DIP switch position
HEAT INPUT
(USGPH)
PreRun On-Delay
CFM Level - Time
ShortRun On-Delay
CFM Level - Time
Off-Delay
CFM Level - Time
A (1=OFF, 2=OFF)
0.85
13% - 45 sec.
44% - 30 sec
38% - 3 min.
B (1=ON, 2=OFF)
1.00
13% - 30 sec.
44% - 30 sec
38% - 3 min.
C (1=OFF, 2=ON)
1.10
13% - 30 sec.
50% - 30 sec
38% - 3 min.
D (1=ON, 2=ON)
All
13% - 30 sec.
100% - 0 sec
100% - 2 min.
No adjustment
required
A/C size
PreRun On-Delay
CFM Level - Time
ShortRun On-Delay
CFM Level - Time
Off-Delay
CFM Level - Time
-
All
No delay
No delay
100% - 90 sec.
PreRun and ShortRun are the periods of time when the the blower starts at very low CFM to minimize the distributon of cool air
Off Delay is the time required to cool down the coil (heating mode) with low CFM, to mimimize cool draft in the air distribution system.
COOLING MODE OR HEAT PUMP HEATING MODE - 2-SPEED LOW
24 VAC input (R) to G, Y1 and O (for cooling)
DELAY PROFILE FOR OIL HEATING MODE
PreRun and ShortRun are the periods of time when the the blower starts at very low CFM to minimize the distributon of cool air
in the system and then runs up to normal speed.
Off Delay is the time required to cool down the heat exchanger with low CFM, to minimize cool draft in the air distribution system.
DELAY PROFILE FOR COOLING OR HEAT PUMP HEATING MODE
in the system and then runs up to normal speed.
Note: In Cooling - Dehumidification mode, with no 24 VAC input to DH, the CFM are reduced by 15%.
Note: In Cooling - Dehumidification mode, with no 24 VAC input to DH, the CFM are reduced by 15%.
OIL HEATING MODE
24 VAC input (R) on W only
Same value as DIP switch position C
CONTINUOUS FAN
24 VAC input (R) on G only
COOLING OR HEAT PUMP HEATING MODE - SINGLE SPEED OR 2-SPEED HIGH
24 VAC input (R) to G, Y/Y2 and O (for cooling)
Содержание CBMAAA060120
Страница 21: ...21 Figure 13 Wiring diagram CVM ...
Страница 22: ...22 Figure 14 Parts list CVMAAR036105 B50003 Rev D ...
Страница 24: ...24 Figure 15 Parts list CVMAAR060120 B50004 Rev F ...
Страница 48: ...23 Figure 13 Diagramme électrique CVM ...
Страница 49: ...24 Figure 14 Liste de pièces CVMAAR036105 B50003 Rev D ...
Страница 51: ...26 Figure 15 Liste de pièces CVMAAR060120 B50004 Rev F ...