![Cabletron Systems SmartSwitch SBU128 Скачать руководство пользователя страница 52](http://html1.mh-extra.com/html/cabletron-systems/smartswitch-sbu128/smartswitch-sbu128_user-manual_3535304052.webp)
Configuration Commands
80-10200000-01
4–23
Default values are shown below (the same for all days):-
Slot
Time
Slot 1
Start time
00:00
End time
24:00
Slots 2, 3, & 4
Start time
00:00
End time
00:00
These defaults ensure that the default Window operation occurs the
same as for auto backup operation, until changes are made to the
window times.
4.5.6.7 ISDNTEST menu
A) ENABLED
B) DISABLED (F)
Enables the daily test call over the
ISDN to check the connection.
C) MANUAL
Effects a test call immediately
without affecting any daily set time.
D) SET TIME
You are prompted to set a daily
time for the test (see below).
When option ’D’ (Set Time) is chosen you prompted as follows:-
‘Enter Test Time (hh:mm):’
This must be terminated with a <cr>.
Valid entries are in the range 00
≤
hh
≤
23 and 00
≤
mm
≤
59. Any other
value or incorrect input gives the following error message and the
original prompt is re-displayed.