background image

INDEX

IX-2

Distributed LAN Monitor 

(DLM)

1-7

Distributed monitoring

DLM

1-7

RMON

1-6

Document

conventions used

xiii

organizational structure

xiv

Documentation, for related 

products

xv

E

EEPROM

1-3

EMC requirements

A-2

Environmental specifications

A-2

F

Fiber optic cable

connecting to ring 

port

4-15 to 4-16

specifications

C-3 to C-4

Flash EEPROM downloads

1-3

Flash image

current version displayed

5-2

memory

A-1

G

Grounded power source

3-1

see also Installation, 

MicroMMAC-T

H

Help

from Cabletron Technical Support 

Department

xvi

from related product 

documentation

xv

I

In-band access to Local 

Management

1-3

Installation

removing the front protection 

panel

3-6

removing the rear protection 

panel

3-8

Installation, accessories

12-port daughterboard

3-9 to 3-10

CRBRIM-W/T

3-12 to 3-13

LDRAM SIMM

3-13 to 3-14

MicroSNAC-T

3-11 to 3-12

TPIM

4-12

Installation, MicroMMAC-T

attaching the strain relief bar

3-2

free-standing

3-4

rack-mounting

3-3

requirements

3-1

Interconnect cable, mandatory use 

when connecting STH hubs to 
the MicroMMAC-T

4-17

L

LANVIEW LEDs

color codes described

5-1

introduction

2-8

monitoring power up

5-10

LCD system

accessing messages

5-2 to 5-7

introduction

2-8

LCD system messages

Saved Alarm Messages

5-3, 5-4

Saved System Messages

5-7

Static System Messages

5-2

Unsaved Initialization 

Messages

5-6

LDRAM SIMM

connector on motherboard

3-9

upgrading

3-13

Содержание MICROMMAC-22T

Страница 1: ...MicroMMAC 22T 24T 42T 44T USER S GUIDE BOOKTITLE2 OPTIONAL...

Страница 2: ......

Страница 3: ...All other product names mentioned in this manual may be trademarks or registered trademarks of their respective companies FCC NOTICE This device complies with Part 15 of the FCC rules Operation is sub...

Страница 4: ...terference in commercial and or industrial areas Consequently when used in a residential area or in an adjacent area thereto radio interference may be caused to radios and TV receivers etc Read the in...

Страница 5: ...SHALL CABLETRON OR ITS SUPPLIERS BE LIABLE FOR ANY DAMAGES WHATSOEVER INCLUDING WITHOUT LIMITATION DAMAGES FOR LOSS OF BUSINESS PROFITS BUSINESS INTERRUPTION LOSS OF BUSINESS INFORMATION SPECIAL INCI...

Страница 6: ...1 EN 60950 Equipment Type Environment Networking Equipment for use in a Commercial or Light Industrial Environment We the undersigned hereby declare under our sole responsibility that the equipment p...

Страница 7: ...nt Information Base MIB Groups 1 9 CHAPTER 2 OPERATION 2 1 Turning The Hub On And Off 2 3 2 2 Control Switches And Buttons 2 4 2 2 1 Setting The Ring Speed 2 4 2 2 2 Resetting The MicroMMAC T 2 5 2 2...

Страница 8: ...mum Signal Drive Distance 4 4 4 3 Connecting Lobe Port Cabling 4 6 4 4 Connecting Trunk Cabling 4 10 4 4 1 Describing TPIMs 4 10 4 4 2 Configuring TPIMs For RI RO Application 4 11 4 4 3 Installing A T...

Страница 9: ...ions A 2 A 4 Physical Specifications A 2 A 5 Safety A 2 A 6 EMC Requirements A 2 APPENDIX B TPIM SPECIFICATIONS B 1 TPIM T1 T2 T4 Pinouts B 1 B 2 TPIM F2 F3 Specifications B 2 APPENDIX C MEDIA SPECIFI...

Страница 10: ...CONTENTS viii...

Страница 11: ...3 4 Figure 3 6 Free Standing Installation 3 4 Figure 3 7 Removing Chassis Cover Screws 3 5 Figure 3 8 Removing The Chassis Cover 3 6 Figure 3 9 Removing The Front Panel 3 7 Figure 3 10 Removing The R...

Страница 12: ...e 4 10 Connecting To The TPIM T2 4 14 Figure 4 11 Connecting To The TPIM F2 F3 4 16 Figure 4 12 MicroMMAC T STH Stack Configuration 4 17 Figure 5 1 Power Up Diagnostic Screen 5 8 Figure B 1 TPIM T1 T2...

Страница 13: ...5 Unsaved Failure Or Error Messages 5 6 Table 5 6 Saved System Messages 5 7 Table 5 7 Power Up Indications From LEDs And The LCD 5 10 Table A 1 Power Supply Outputs A 1 Table B 1 TPIM F2 Receiver Spe...

Страница 14: ...TABLES xii...

Страница 15: ...re used throughout this manual Bold Italics are used for references in non tabular text to Cabletron Systems publications and other publications MicroMMAC T collectively refers to the MicroMMAC 22T Mi...

Страница 16: ...ling guidelines for Token Ring networks and how to connect network cable to MicroMMAC T lobe ring and stack ports Chapter 5 Monitoring and Troubleshooting describes how to use the system message LCD L...

Страница 17: ...ea Networks IEEE Standard 802 5 Token Ring Access Method And Physical Layer Specifications Commercial Building Wiring Standard EIA TIA 568A Standard Device Installation Operation Management MicroMMAC...

Страница 18: ...ize at the time of trouble if known The serial and revision numbers of all Cabletron Systems products in the network MicroMMAC T information listed on its Local Management Password screen The device h...

Страница 19: ...ive RJ45 lobe ports that support category 3 4 and 5 UTP cabling MicroMMAC 24T 24 active RJ45 lobe ports that support category 3 4 and 5 UTP cabling MicroMMAC 42T 12 active shielded RJ45 lobe ports tha...

Страница 20: ...the port has detected a speed fault violation and has been put into the bypassed mode See Section 5 1 for information about monitoring the MicroMMAC T using LANVIEW LEDs Lobe Port To Ring Port Convers...

Страница 21: ...ges you can use to fully exploit the MicroMMAC T s management capabilities SPECTRUM Remote LANVIEW Windows Spectrum Element Manager Remote SPECTRUM Portable Management Application SPMA for the MicroMM...

Страница 22: ...s feature ensures that other stations are not prevented from inserting into the ring by a unresolved ring poll failure condition caused by a malfunctioning station on the ring Upon detecting the prese...

Страница 23: ...AC T detects excessive error frames Beacon Claim Token or Purge MAC frames on the ring that is frames in amounts exceeding tolerable thresholds associated with normal ring functioning The ABRP consist...

Страница 24: ...the component containing the groups RMON component groups are listed and briefly described as follows RMON Default Component Statistics Group Records frame traffic and network performance statistics...

Страница 25: ...ation that has DLM configuration capabilities Cabletron s SPMA for the MicroMMAC T for example For both operations the MicroMMAC T maintains a database specified in the DLM application of devices to b...

Страница 26: ...2 to SDLC data link protocol conversion device enabling you to integrate data from Token Ring and SNA networks With the addition of custom software modules designed to expand its functionality the Mic...

Страница 27: ...to 24 for the MicroMMAC 22T UTP lobe port model and the MicroMMAC 42T STP lobe port model by installing the 12 port daughterboard designed for each model The daughterboard installs in the MicroMMAC T...

Страница 28: ...INTRODUCTION 1 10...

Страница 29: ...areas Connecting to a power source turning the hub ON and OFF Working with console switches and buttons Setting the ring speed Resetting the hub Clearing Non Volatile Random Access Memory NVRAM Worki...

Страница 30: ...17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 4M 16M SPEED MicroMMAC 24T TOKEN RING HUB WITH LANVIEW LINE 100 125V 4 0A 200 250V 2 0A 50 60Hz SN STACK2 STACK3 STACK4 STACK5 RESET S0 CONSOLE S0 S1 PWR TR S...

Страница 31: ...ctor to the male power source connector on the hub Figure 2 2 Connecting To A Power Source 2 Plug the power cord s male connector into a grounded power outlet After a two to three minute interval duri...

Страница 32: ...ed 1 Slide the ring speed switch to the setting you want 2 Reset theMicroMMAC T as described in Section 2 2 2 3 Check the 16Mb s LED to verify the ring speed after the reset The 16Mb s LED lights yell...

Страница 33: ...ve pointed tip instrument into the recessed RESET switch hole 2 Press the switch once and then release LEDs the LCD panel and the Power Up Diagnostic screen indicate that the MicroMMAC T is running in...

Страница 34: ...SET switch to clear NVRAM only when you want to revert to default system settings Figure 2 5 NVRAM Switch To clear NVRAM 1 Make sure the MicroMMAC T is turned on CAUTION Do not reposition the NVRAM sw...

Страница 35: ...LEDs The MicroMMAC T s LANVIEW LED monitoring and diagnostic system shown in Figure 2 6 consists of two sets of LEDs System LEDs CPU 16Mb s ACT MGMT Port Status LEDs 1 to 24 Figure 2 6 LANVIEW LEDs S...

Страница 36: ...2 7 consists of two components the LCD panel and the DISPLAY button The LCD panel displays information about operational parameters and events occurring in the MicroMMAC T and on the network It autom...

Страница 37: ...AY button two second to display the first message Press and immediately release to view each additional message See Section 5 2 for a complete description of LCD messages Figure 2 7 LCD Panel And DISP...

Страница 38: ...ply UPS SNMP monitoring connection See the Console Cable Kit Instruction Sheet include with the MicroMMAC T for information about using the UPS adaptor to set up the UPS connection Out of band LM acce...

Страница 39: ...ports shown in Figure 2 9 for all models are internally crossed over and support connection to straight through cable conforming to EIA TIA 568 standards Figure 2 9 Lobe Ports See Section 3 2 4 for i...

Страница 40: ...orts Figure 2 11 Ring Ports See the MicroMMAC T Local Management Guide for information about enabling and disabling RI RO ports and Section 4 4 for a description of TPIM models and instructions on con...

Страница 41: ...that any enclosure in which the MicroMMAC T is installed is at least 21 inches wide 18 inches deep and 6 inches high to provide adequate ventilation see Figure 3 6 Use a single phase 100 to 250 Vac g...

Страница 42: ...m the MicroMMAC T installation kit 2 Align the holes on the strain relief bar with the holes on the bottom of the MicroMMAC T and then attach the bar with the screws as shown in Figure 3 2 CAUTION Do...

Страница 43: ...MicroMMAC 24T TOKEN RING HUB WITH LANVIEW SUPPORTING 100 OHM UTP CABLE COM 1 COM 2 RI 2 4 2 3 2 2 2 1 2 0 1 9 1 8 1 7 1 6 1 5 1 4 1 3 CONSOLE PORT 2 PORT 1 RST XMT RCV XMT RCV MicroSNAC T FLT ACT V35...

Страница 44: ...stallation R DISPLAY RESET 4M 16M SPEED CPU 16Mb s ACT MGMT RO 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 MicroMMAC 24T TOKEN RING HUB WITH LANVIEW SUPPORTING 100 OHM UTP CABLE COM...

Страница 45: ...configuring and installing TPIMs used for Ring In Ring Out ports 3 2 1 Removing The Chassis Cover To remove the chassis cover 1 Remove the screws from the hub as shown in Figure 3 7 Figure 3 7 Removin...

Страница 46: ...board and the rear protection panel to install the CRBRIM W T Removing the Front Protection Panel To remove the front protection panel 1 Remove the MicroMMAC T chassis cover as described in Section 3...

Страница 47: ...NFIGURED AS A MicroMMAC 42T TO UPGRADE TO A MicroMMAC44T ORDER PART NUMBER TR STP UGKIT 12 11 10 9 8 7 6 5 4 3 2 1 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 24 23 22 21 20 19 18 1...

Страница 48: ...MAC T rear panel and then remove the protection panel from the aperture as shown in Figure 3 10 Keep the protection panel handy for future reattachment Figure 3 10 Removing The Rear Panel 3 2 3 Connec...

Страница 49: ...for the MicroMMAC 42T To install the daughterboard 1 Remove the MicroMMAC T chassis cover as described in Section 3 2 1 and the front protection panel as described in Section 3 2 2 CAUTION Do not atte...

Страница 50: ...12 Installing The 12 port Daughterboard 3 Secure the daughterboard to the support posts with the support post screws and then put the chassis cover back on CAUTION If you feel excessive resistance wh...

Страница 51: ...ion panel as described in Section 3 2 2 2 Lower the daughterboard on to the support posts as shown in Figure 3 13 aligning the front of the 12 port daughterboard flush against the aperture and inserti...

Страница 52: ...in Figure 3 14 aligning the front of the BRIM flush against the rear panel aperture and inserting the BRIM connector pins completely into the connector The pins should insert easily into the connector...

Страница 53: ...component functions See Figure 3 11 for the location of the LDRAM SIMM connector To exchange SIMMs 1 Remove the 4 MB SIMM as shown in Figure 3 15 CAUTION If you feel excessive resistance while inserti...

Страница 54: ...AM SIMM Push the retraction handles out Lift the SIMM from the connector Retraction Handle Push the SIMM back against Lower the SIMM into the connector positioning the notch on the SIMM on the rib in...

Страница 55: ...media types Fiber provides the greatest data transmission distance capability and signal interference immunity and STP provides greater data transmission distance capability and signal interference im...

Страница 56: ...cks for example Figure 4 2 and Figure 4 3 show examples of multi segment lobe cabling setups 4 2 REQUIREMENTS AND RECOMMENDATIONS This section provides cabling requirements and recommendations for the...

Страница 57: ...s significantly with temperature Check the cable manufacturer s specifications Plenum rated cables are strongly recommended in areas where temperatures exceed 40 C Under such conditions plenum rated c...

Страница 58: ...distance achievable from an aggregate Token Ring cabling installation is dependent on the following factors Media types used for both lobe and trunk cabling in the installation and the drive distance...

Страница 59: ...ypes 6 9 For station to wall jack or patch panels only 30 meters 99 feet 30 meters 99 feet UTP Category 3 4 200 meters 656 feet 100 meters 328 feet UTP Category 5 250 meters 820 feet 120 meters 394 fe...

Страница 60: ...your network manager or any of the Cabletron Systems technical support resources for assistance with designing a fault resistant Token Ring cabling scheme Working With Mixed STP Cable Types If STP ca...

Страница 61: ...letron Systems TRMF and TRMF 2 media filters are available for UTP to STP impedance matching The Cabletron Systems T2015 and T3015 DNI cards are equipped with ports supporting both UTP and STP lobe li...

Страница 62: ...ts provides a cross reference of pinouts for cable connectors which may be used for lobe segments Table 4 3 Connector Pinout Cross Reference Signal RJ45 MIC DB9 Tx 3 Black 1 Rx 4 Red 9 Rx 5 Green 5 Tx...

Страница 63: ...station tried to insert into the ring at the wrong ring speed Figure 4 4 Connecting To A Lobe Port If the associated Port Status LED lights red or does not light perform the following steps to resolve...

Страница 64: ...2 for instructions on configuring TPIMs for RI RO application and installation instructions See Appendix B for TPIM pinouts and TPIM performance specifications Figure 4 5 TPIMs Table 4 4 lists TPIMs...

Страница 65: ...T4 after you have established the link Figure 4 6 TPIM Configuration Settings CAUTION Setting the phantom switch to 0 non Cabletron device on the TPIM T1 T2 T4 before connecting the device to it will...

Страница 66: ...t are fully inserted into the connector on the TPIM The LNK LED on the TPIM lights Red for the TPIM T1 T2 T4 only indicating successful TPIM insertion into an activated MicroMMAC T the MicroMMAC T det...

Страница 67: ...s of the connection using the LNK LED Connecting STP Use the TPIM T1 to connect an STP trunk cable segment with a DB9 connector as shown in Figure 4 8 Use the TPIM T4 to connect an STP trunk cable seg...

Страница 68: ...t been established If the LNK LED on the TPIM T1 T2 T4 lights red or does not light perform the following steps to resolve the problem 1 Ensure that both hubs are powered up and that the ring ports on...

Страница 69: ...ou label fiber optic cable to indicate which end of a fiber strand connects to a Receive port and which end connects to Transmit port By using such a labeling scheme you can eliminate the possibility...

Страница 70: ...or blinks green if a connection has not been established If the LNK LED on the TPIM F2 F3 does not light green perform the following steps to resolve the problem 1 Ensure that both hubs are powered up...

Страница 71: ...bSTACK Interconnect cables order number 9380141 to connect the STH hubs to the MicroMMAC T STACK ports NOTE It is recommended but not required that you connect the STH hubs to the MicroMMAC T in logic...

Страница 72: ...th the physical connection or the MicroMMAC T and the STH hub are set to operate at different ring speeds Any STH hub with a different ring speed is automatically bypassed from the MicroMMAC T s host...

Страница 73: ...e Port Status Ports 1 24 Off Green Red solid Red blinking No Link Port Enabled Link Port Enabled Port Disabled Ring Out Status Link or Ring Speed Fault Port Disabled 16Mb s Ring Speed Yellow Off 16 Mb...

Страница 74: ...ide information about the MicroMMAC T s operating code and network identity To view Static System messages 1 Press and then immediately release the DISPLAY button to display the first Static System me...

Страница 75: ...name if the DISPLAY button is not pressed again within ten seconds Table 5 3 Alarm Messages Message What It Means NO MESSAGES IN QUEUE No alarm messages are in the queue TPIM Inserted A TPIM was inse...

Страница 76: ...Stack x Port xx An STH lobe port number 1 to 24 detected a speed fault error and is disabled Ring Threshold Ring Purges The ring purge error count has exceeded the threshold parameters set in an SNMP...

Страница 77: ...s set in an SNMP application for one or more stations on the ring Ring Poll Fail Detected The active monitor has generated a Neighbor Notification Incomplete frame as a result of a station s failure t...

Страница 78: ...ical Support for assistance Table 5 4 Unsaved Initialization Messages Bit Swap Test MicroMMAC xx Cabletron Boot Complete Programming LRAM Boot From Flash RARP Req State BOOTP Discovery Test in Progres...

Страница 79: ...to the product name if the DISPLAY button is not pressed again for ten seconds Table 5 6 Saved System Messages Message What It Means BootP Host xxx xxx xxx xxx The IP address of the BootP server from...

Страница 80: ...sages they may produce To view the test connect your management terminal or PC to the MicroMMAC T COM 2 port prior to power up or reset Responding to a Power Up Error Message Figure 5 1 depicts an exa...

Страница 81: ...ngle retry of the test producing the error message loop Repeatedly retries the test producing the error message To stop the loop press the Delete key To execute a response option 1 Type the option c r...

Страница 82: ...rom LEDs And The LCD Initialization Phase What LEDs Indicate What the LCD Indicates Self Tests CPU solid yellow ACT off 16Mb s solid yellow MGMT solid red Test in Progress CPU solid green ACT off 16Mb...

Страница 83: ...d that it is free from physical design errors Check that each cable connection is secure Verify the pinouts for each connection Use a cable tester to check the cable conductors for continuity 2 Ensure...

Страница 84: ...MONITORING AND TROUBLESHOOTING 5 12...

Страница 85: ...letron Systems Technical Support as described in the Preface for information on expanding FLASH CPU and Shared memory A 2 POWER SUPPLY SPECIFICATIONS The power supply has two outputs of 5 volts and 12...

Страница 86: ...non condensing A 4 PHYSICAL SPECIFICATIONS Dimensions 2 8H x 17 0W x 13 5D inches 7 2H x 43 6W x 34 6D centimeters Weight 7 pounds A 5 SAFETY This unit meets the safety requirements of UL 1950 CSA C2...

Страница 87: ...mit 2 Ground 3 5V at 250mA 4 Ground 5 Receive 6 Transmit 7 Ground 8 Ground 9 Receive 1 Receive 2 Ground 3 5V at 250mA 4 Ground 5 Transmit 6 Receive 7 Ground 8 Ground 9 Transmit RING IN 1 Not Used 2 No...

Страница 88: ...Table B 1 TPIM F2 Receiver Specifications Test Conditions TA 25 C Parameter Typical Minimum Receive Sensitivity 30 5 dBm 32 0 dBm Peak Input Power 7 6 dBm 8 2 dBm Rise Time 3 3 ns Fall Time 3 3 ns Bit...

Страница 89: ...dBm average Table B 3 TPIM F3 Specifications Parameter Typical Minimum Maximum Transmitter Peak Wave Length 1300 nm 1270 nm 1330 nm Spectral Width 100 nm Rise Time 2 5 nsec 5 0 nsec Fall Time 3 5 nse...

Страница 90: ...TPIM SPECIFICATIONS B 4...

Страница 91: ...and the TPIM T2 support UTP cable categories 3 4 and 5 which are described as follows Category 3 or 10BaseT UTP cable consists of four unshielded twisted pairs of 24 AWG solid wire for data or voice c...

Страница 92: ...22 AWG solid wire for data It is typically used for the longest cable runs within building walls of buildings IBM Type 2 is similar to Type 1 data cable but it has four additional UTP lengths of 22AWG...

Страница 93: ...e layers of reinforced matter are wrapped around the fibers for protection There are two basic fiber optic cable types multimode and single mode Single mode fiber is typically used for long run or bac...

Страница 94: ...ess 2 km 2187 7 yards Multimode 62 5 125 m 16 0 dB or less 2 km 2187 7 yards Multimode 100 140 m 19 0 dB or less 2 km 2187 7 yards Typical Signal Attenuation Rate 1 5 dB km Table C 4 Signal Tolerance...

Страница 95: ...verview terminology 4 1 to 4 2 see also Lobe cabling Trunk cabling Cabling signal interference crosstalk 4 3 noise 4 3 temperature 4 3 Cabling STH hubs connecting to MicroMMAC T 4 17 to 4 18 using Hub...

Страница 96: ...Local Management 1 3 Installation removing the front protection panel 3 6 removing the rear protection panel 3 8 Installation accessories 12 port daughterboard 3 9 to 3 10 CRBRIM W T 3 12 to 3 13 LDR...

Страница 97: ...M A 1 upgrading LDRAM 3 13 MGMT LED 5 1 MIBs 1 9 MicroMMAC T available models 1 1 features 1 2 to 1 9 getting help xvi MIB support 1 9 power up connecting to a power source 2 3 removing the chassis co...

Страница 98: ...k cabling Single mode fiber optic cable connecting to ring port 4 15 specifications C 4 SNMP support 1 3 Speed fault protection 1 2 SPEED switch setting ring speed with 2 4 STACK port 2 12 4 17 to 4 1...

Страница 99: ...b 4 18 when connecting twisted pair trunk cable segments 4 14 Trunk cabling connecting 4 10 to 4 16 described 4 1 maximum lengths 4 5 U Uninterruptible Power Supply UPS 1 8 Unshielded Twisted Pair UTP...

Страница 100: ...INDEX IX 6...

Страница 101: ...die Anwendung des Geraetes geeignet und der zum Benuetzen im Lande der Anwendung anerkannt ist SPANISH El cable principal de la red el ctrica utilizado con este equipo debe tener 2 conductores y 1 to...

Отзывы: