SETTING THE EMME MODE SWITCHES
EMME USER’S GUIDE
Page 3-3
Switches should be positioned as follows:
•
Switch 1 - NMI (Non-Maskable Interrupt). This switch must be in the
On position. Cabletron Systems use only.
•
Switch 2 - STESTDIS (System Test Disable). This switch must be in
the Off position. Cabletron Systems use only.
•
Switch 3 - CADIC (Software Debugging Tool). For manufacturing use
only. Keep in Off position.
•
Switch 4 - MIMREV (Management Interface Module Revision). This
switch must be in the Off position for normal operation. Only if you
are using THN-MIM part numbers 9000043-05 and below in your
MMAC-FNB, the switch must be in the On position.
•
Switch 5 - Baud Rate Default. Allows you to set the Console port’s
baud rate. The Off position sets the baud rate to 9600. The On position
sets the baud rate to 2400.
•
Switch 6 - Forced Download. Changing the position of this switch
after pulling the board out of the MMAC-FNB, clears download
information from NVRAM and forces image files to be downloaded
from the station configured to act as that EMME’s BOOTP server.
WARNING
Never adjust switch settings on the EMME while there is
power applied to it. Slide the EMME out of the chassis and
change the switch as needed to select a function. The
function is initiated when the EMME is reinstalled.