BOOT Failures
CSMIM-T1 Hardware Installation Guide
5-9
Activity TE2: Hardware Failure
The ROM diagnostics detected a CSMIM-T1 hardware problem requiring
service. Call Technical Support.
Activity TE7: Booted Wrong Image
The CSMIM-T1 loaded an inappropriate image. Press the SETUP button
for three seconds to reset the device. Following is a list of ways to prevent
this problem in the future:
•
Be sure that you configure the CSMIM-T1 with the appropriate image
(
oper.46.enet
).
•
Be sure that the image you are booting has the right name. Don’t
rename the image file unless you are making a copy for safe keeping.
•
If you used an na, admin, or cli boot command, specify the correct
image and a valid filename.
5.3
BOOT FAILURES
The procedures for troubleshooting a power-up failure established that
•
The hardware is functional.
•
The Ethernet interface is functional.
•
The CSMIM-T1 can communicate with the Ethernet.
If the CSMIM-T1 still is not booted, you must pinpoint the problem. The
boot error report can help in this process.
Generally, two problems cause boot failures:
•
The CSMIM-T1 is not configured properly.
•
The load server host is not responding.
NOTE
The CSMIM-T1generates a boot error report only if it opens the
boot file and an error occurs during the boot process.
Содержание CSMIM-T1
Страница 2: ......
Страница 8: ...viii CSMIM T1 Hardware Installation Guide ...
Страница 26: ...Chapter 1 INTRODUCTION 1 14 CSMIM T1 Hardware Installation Guide ...
Страница 84: ...Chapter 4 CSMIM T1 Parameters 4 16 CSMIM T1 Hardware Installation Guide ...
Страница 184: ...Chapter 7 AT Commands and Registers 7 58 CSMIM T1 Hardware Installation Guide ...
Страница 188: ...Appendix A PORT PIN SIGNAL ALLOCATIONS A 4 CSMIM T1 Hardware Installation Guide ...