Chapter 7: AT Commands and Registers
7-36
CSMIM-T1 Hardware Installation Guide
CONNECT <speed>/REL-MNP or
CONNECT <speed>/REL-LAPM or
CONNECT <speed>/REL-CELLULAR
\V5
Displays \V4 plus modulation V.34, V.FC, V.32, or V.22.
Determines whether result codes indicate that a reliable link
connection is in effect. The W setting determines the contents of
the <speed> field. Setting -M1 changes the format of the
long-form connect result codes.
Even for a reliable connection, use \V0 if the communications
software does not expect to see a reliable link result code.
Use \V1, \V2, \V3, \V4 or \V5 when your software supports error
correction result codes.
Use V0\V3 if your communications software requires
Hayes-compatible connection result codes. Note that when V1 is
set to select long-form result codes \V3 is equivalent to \V1.
Use \V3, \V4 or \V5 to see actual connect speed.
^V
Display Bootstrap Revision
Requests modem to display its current flash memory bootstrap
revision.
W
n
Connection Speed Reporting
W0
Displays serial-port connect messages.
W1
Displays serial-port connect messages.
W2
Displays modem-port connect messages.
When W0 or W1 is set, the speeds reported in connect messages
indicate the serial-port speed.
When W2 is set, the speeds reported in connect messages indicate
the modem-port speed.
NOTE
When either \V1 or \V2 is set, the message CONNECT
9600/REL displays during 4800, 7200, and 12000 bps reliable
connections. When either \V3 or \V4 is set, the actual modem
bps rate displays for 4800, 7200, and 12000 bps reliable
connections.
Содержание CSMIM-T1
Страница 2: ......
Страница 8: ...viii CSMIM T1 Hardware Installation Guide ...
Страница 26: ...Chapter 1 INTRODUCTION 1 14 CSMIM T1 Hardware Installation Guide ...
Страница 84: ...Chapter 4 CSMIM T1 Parameters 4 16 CSMIM T1 Hardware Installation Guide ...
Страница 184: ...Chapter 7 AT Commands and Registers 7 58 CSMIM T1 Hardware Installation Guide ...
Страница 188: ...Appendix A PORT PIN SIGNAL ALLOCATIONS A 4 CSMIM T1 Hardware Installation Guide ...