Setting the Chassis Time
To set the chassis clock, perform the following steps:
1.
Use the arrow keys to highlight the Chassis Time field.
2.
Enter the time in this 24-hour format: HH:MM:SS
3.
Press ENTER to set the system clock to the time in the input field.
4.
Use the arrow keys to highlight the SAVE command at the bottom of
the screen and press ENTER.
If the time entered is a valid format, the Event Message Line at the top of
the screen displays “SAVED OK”. If the entry is not valid, Local
Management does not alter the current value and refreshes the Chassis
Time field with the previous value.
5.7.5
Entering a New Screen Refresh Time
The screen refresh time is set from 3 to 99 seconds with a default of 3
seconds. To set a new screen refresh time, perform the following steps:
1.
Use the arrow keys to highlight the Screen Refresh Time field.
2.
Enter a number from 3 to 99.
3.
Press ENTER to set the refresh time to the time entered in the input
field.
4.
Use the arrow keys to highlight the SAVE command at the bottom of
the screen and press ENTER.
NOTE
When entering the time in the system time field, separators
between hours, minutes, and seconds do not need to be added
as long as each entry uses two numeric characters. For
example, to set the time to 6:45
A
.
M
., type “064500” in the
Chassis Time field.
NOTE
Upon saving the new chassis time, all interface modules
installed in the chassis recognize the new value as the current
time.
Содержание 6H133-37
Страница 2: ......
Страница 8: ...Notice vi 6H123 50 and 6H133 37 User s Guide...
Страница 14: ...Contents xii 6H123 50 and 6H133 37 User s Guide...
Страница 28: ...Chapter 1 Introduction 1 14 6H123 50 and 6H133 37 User s Guide...
Страница 50: ...Chapter 4 Troubleshooting 4 10 6H123 50 and 6H133 37 User s Guide...
Страница 186: ...Appendix A Specifications A 4 6H123 50 and 6H133 37 User s Guide...
Страница 190: ...Appendix B FE 100TX FE 100FX and FE 100F3 Specifications B 4 6H123 50 and 6H133 37 User s Guide...
Страница 198: ...Appendix C Optional Installations and Mode Switch Bank Settings C 8 6H123 50 and 6H133 37 User s Guide...
Страница 204: ...Index Index 6 6H123 50 and 6H133 37 User s Guide...