7.2 Explanation of the Signals
Pin
Signal
Description
Activation /
Active State
1
XSTART
Start signal
triggers the start of the print when using the
“Cut on demand“ operating mode,
This signal is checked if there is a connec-
tion between signal STA and ground GND.
Switch on +24 V
between Pin 1
and Pin 9
2
XFEH
External error
An error has occurred in an externally con-
trolled device.
The label print is stopped and the display
of the printer shows the message "External
error".
After the error is corrected, it is possible to
press the pause key and the print job will
continue. The last label printed before the
error occurred will be repeated. Pressing
the cancel key will stop the print job and the
printer will be reset.
Switch on +24 V
between Pin 2
and Pin 10
3
-
-
4
-
-
5
XEDG
No existing print job
There is no print job currently available.
Contact between
Pin 5 and Pin 14
is open
6
XDNB
Printer is not ready
An error has occurred on the printer.
The label print is stopped and the details
and type of error can be read from the
printer display ('Ribbon out'; 'Paper out'; 'No
label')
Contact between
Pin 6 and Pin 14
is open
7
XEDST
Print of label has started
The printing of a label is indicated with a
20 ms pulse.
Contact between
Pin 7 and Pin 14
is open
8
GND
Ground ( 0 V )
9
RX-
START
Start signal (reverse line)
10
RXFEH
External error (reverse line)
11
-
-