cab Produkttechnik GmbH & Co KG
175
175
[TABLE OF CONTENTS] [COMMAND LIST]
Hermes
Apollo
A-series
This
function is
available
for:
PRODUCT MARKING AND BARCODE IDENTIFICATION
M-series
[SEC] Print
SEC
onds (00-59)
This option is used to recall the actual seconds from the printer´s internal clock. Usually this option is
used together with the options [H...] and [MIN].
[SEC]
J
S l1;0,0,68,71,100
T 12,25,0,3,6;Actual time is [H024]:[MIN]:[SEC]
A1
In this example the result is identical to the TIME option.
The difference is that the seconds can be printed separately.
Syntax:
Example: