cab Produkttechnik GmbH & Co KG
41
41
[TABLE OF CONTENTS] [COMMAND LIST]
Hermes
Apollo
A-series
This
function is
available
for:
PRODUCT MARKING AND BARCODE IDENTIFICATION
M-series
ESC
s
Printer
s
tatus query
ESCs Printer
s
tatus query,which responds through the interface
ESCs
XYNNNNNNZ
where:
X = Online (Y=Yes, N=No)
Y = Type of error:
NNNNNN = amount of labels to print
Z = Interpreter active (Y=Yes = print job is in process, N=No= printer in Standby mode)
- --------------------------------------------------------------------------------- No error
a ---- Applicator error- -------------------------- applicator in upper position *
b ---- Applicator error- --------------------------- applicator in lower position*
c ---- Applicator error– ------------------------------- vacuum plate is empty*
d ---- Applicator error- ------------------------------------ label not deposited*
e ---- Applicator error- ------------------------------------------- host stop/error*
f ----- Applicator error- - reflective sensor blocked/ scanresult negative*
g ---- Applicator error ----------------------------------------------------- 90° error
h ---- Applicator error ------------------------------------------------------- 0° error
i ----- Applicator error -------------------------------- table not in front position
j ----- Applicator error -------------------------------- table not in rear position
k ---- Applicator error --------------------------------------------------- head liftet
l ----- Applicator error -------------------------------------------------- head down
B ------------------------------------------------------------------------ Protocol error
C ------------------------------------------------------------------ Memory card error
D ---------------------------------------------------------------------- Printhead open
E ---------------------------------------- Synchronization error (No label found)
F ------------------------------------------------------------------------ Out of Ribbon
H ---------------------------------------------------------- heating voltage problem
M ---------------------------------------------------------------------- Cutter jammed
N ------------------------------------------------- Label material too thick (cutter)
O --------------------------------------------------------------------- Out of memory
P -------------------------------------------------------------------------- Out of paper
S -------------------------------------------------------- Ribbon saver malfunction
V --------------------------------------------------------------- Input buffer overflow
W ----------------------------------------------------------- Print head over heated
X ------------------------------------------------------------------- External I/O error
Z ---------------------------------------------------------------- Printhead damaged
n ------------------------------------------------------------------------- network error
u ----------------------------------------------------------------------------- USB error
Note: Immediately when a job has started the printer will send a Y and sets this value back to N when
the last label of this job is printed.
*A status request can only be processed through the serial interface on Apollo and Hermes with an
attached applicator !
Syntax:
Example: