![background image](http://html1.mh-extra.com/html/cab/a-series/a-series_programming-manual_3173685171.webp)
cab Produkttechnik GmbH & Co KG
171
171
[TABLE OF CONTENTS] [COMMAND LIST]
Hermes
Apollo
A-series
This
function is
available
for:
PRODUCT MARKING AND BARCODE IDENTIFICATION
M-series
[H24] Print
H
our in
24
-hour form (0-23)
This option is used to recall the time from the printer´s internal clock. The result will be the actual
hour on the label in the 24 hour format. Usually this option is used together with the options [MIN] and
[SEC] .The single digits (1..9) are printed without leading zeroes.
[H24]
J
S l1;0,0,68,71,100
T 12,25,0,3,9;The hour is [H24]
A1
Syntax:
Example: