![background image](http://html2.mh-extra.com/html/c-tech/16-t0012-p/16-t0012-p_product-manual_5010712010.webp)
- 8 -
Configure ramming weight (according to DIN 22476-2)
DPL(10kg drop weight X 0.5m drop height):
Operation without additional weight.
DPM (30 kg drop weight x 0.5 m drop height):
Add additional weight with the side of the larger inner diameter forward via the ram probe and place
on the impact socket of the 16-T0012/P. Slide the fastening clamp all the way to the additional weight
and tighten it well. Make sure that the blow-off hole, which is now behind the additional weight,
remains free.
Perform ramming
1.
The compressed air supply line from the appropriate compressed air source (technical data see
5.1) must be provided with the appropriate clutch nipple on the exit side.
ATTENTION!
Observe the required performance data of the compressed air source (see 5.1).
Operating with too high pressure or unsuitable air can lead to damage to the 16-
T0012/P and risk of accidents.
2.
When the compressor is off, spray oil through the plug-in clutch nipple into the hose line, or lift
the cylinder tube slightly and spray oil through the now visible gap above the control seal.
3.
With the regulating valve open, connect the compressed air hose to the brass coupling of the
ram probe. The ram probe starts to beat when the regulating valve is closed and can thus be set
to the desired number of strokes per minute.
The ram probe must not hit top dead center, but must trigger and fall down before the cylinder
is fully extended and strikes. Striking the upper end of the piston rod leads to falsified
measurement values and can damage the device and lead to accidents.
WARNING!
If the piston rod limit is broken, there is a risk of injury if the ram cylinder jums out
of the piston rod guide.
Содержание 16-T0012/P
Страница 1: ...I Dynamic Cone Penetrometer 16 T0012 P...
Страница 16: ...14 Note all the above showing pics and sketchs are for reference only Gap 1 2 mm...
Страница 19: ...17...