5
9.
Programming guide
10.
Anti-tamper alarm
When the unit is removed illegally the anti-tamper switch will be activated and the internal alarm will
sound for one minute. Or it can be turned off in the following ways: Input
.
Master fingerprint
.
or
.
User
fingerprint
.
or
.
Master code
.
To enter programming mode
.
*
.
Master code
.
#
.
9999 is the default master code
To exit programming mode
.
*
.
Note that to undertake the following programming the master user must be logged in
To change the master code
.
0
. .
New code
.
.
#
. .
New code
.
.
#
.
The master code is any 4 digits
To add a fingerprint
.
1
.
ID code
.
#
. .
Input fingerprint
.
.
Input fingerprint
. .
#
.
ID code range is 1 to 1000. ID code 1 is master add fingerprint, ID code 2 is master delete fingerprint, ID code 3 to
1000 are users’ fingerprints. Each ID code be assigned one fingerprint, master fingerprints must be added by ID code.
Advice for adding fingerprints:
when the LED lights up, input fingerprint. It gives a short beep when the fingerprint is
inputted for the first time. Release fingerprint, then input the same fingerprint again. The unit will emit a longer beep
and the LED will turn green, this means the fingerprint has been successfully added. If the operation has failed, three
short beeps will be emitted, attempt the process again. In order to improve the success rate, please put middle of the
fingerprint on the middle of the induction area.
To add users continuously
ID code will be auto generated, from 3
to 1000
.
7
. .
1
st
user fingerprint twice
.
…
.
Nth user fingerprint
twice
. .
#
.
To delete a fingerprint
.
2
. .
ID code
.
.
#
.
Users can be deleted continuously without exiting programming mode
To delete users continuously
Each fingerprint only needs to be
inputted once
.
8
. .
1
st
user fingerprint
.
…
.
Nth user fingerprint
. .
#
.
To delete all fingerprints
This process deletes all users, so use
with care
.
2
.
0000
.
#
.
Add/delete users by master fingerprints
To add fingerprint users
Input
.
Master add fingerprint
.
.
1
st
user fingerprint twice
.
…
.
Nth user fingerprint twice
. .
Master add fingerprint
.
To delete fingerprint users
Input
.
Master delete fingerprint
.
.
1
st
user fingerprint
.
…
.
Nth user fingerprint
.
.
Master delete fingerprint
.
To set door open time
.
4
.
0 – 99
.
#
.
0 – 99 is to set the door relay time to 0 – 99 seconds
To unlock the door
In standby state, input valid user fingerprint, door will open