Thank you for buying this RESOL product.
Please read this manual carefully to get the best performance from this unit.
Please keep this manual carefully.

Summary of Contents for DeltaSol MiniPool

Page 1: ...niPool Mounting Connection Operation D e lt a S o l MiniPool EN Manual 48004880 48004880 Thank you for buying this RESOL product Please read this manual carefully to get the best performance from this unit Please keep this manual carefully ...

Page 2: ... compliance with the technical data specified in this manual Improper use excludes all liability claims CE Declaration of conformity The product complies with the relevant directives and is therefore labelled with the CE mark The Declaration of Conformity is available upon request please contact RESOL Note Notes are indicated with an information symbol Î Î Arrows indicate instruction steps that sh...

Page 3: ... is possible Display graphic display 160 x 64 px Operation 3 push buttons at the front Functions controller for heating a swimming pool by means of solar ab sorbers in combination with the opti mised operation of the filter system Solar loading When the absorber temperature is by an adjusted value higher than the pool temperature solar loading starts If the difference between flow and pool falls b...

Page 4: ...ug and screw leaving the head protruding Î Î Hang the housing from the upper fastening point and mark the lower fastening point through the hole in the terminal box centres 130 mm Drill and insert the lower wall plug Î Î Fasten the housing to the wall with lower fastening screw and tighten Î Î Carry out the electrical connections according to the specifications Î Î Refasten the cover 2 Installatio...

Page 5: ... L N R1 N R2 N 20 19 18 17 16 15 S4 7 8 14 13 12 DeltaSol Minipool 220 240V VBus 9 10 2 1 A 220 24 0 V T1 25A Connecting the device to the power supply must always be the last step of the installation The power supply of the device must be 220 240 V 50 60 Hz 2 2 2 Data communication Bus The controller is equipped with the RESOL VBus for data transfer with and energy supply to external modules The ...

Page 6: ...able R1 R2 Filter pump P1 3 way valveV1 Solar on off Sensor Description Tabsorber Absorber temperature Tpool Pool temperature Tflow Flow temperature S4 freely selectable with WMZ Treturn Treturn Return temperature Sensor abbreviations D e lt a S o l MiniPool RESOL 09225 DeltaSol_MiniPool monen indd 6 ...

Page 7: ... Press button 3 again to store the adjustment The con troller will then go back to the adjustment menu If button 3 is not pressed after the adjustment the display will go back after a few seconds The adjustment will not be stored Selecting a function or option Î Î Select the desired function or option by pressing but tons 1 and 2 then briefly press button 3 Î Î Select Yes to activate the selected ...

Page 8: ...ining time is displayed Additionally possible causes for the Solar on and Solar off status of the system are indicated Pool Max Maximum pool temperature is reached Flow Max Maximum flow temperature is reached Abs max Maximum absorber temperature is reached Abs min Minimum absorber temperature is reached Sensor failure Min On Minimum runtime is active Min Off Minimum break time is active D e lt a S...

Page 9: ...er hours R1 Operating hours of the filter pump P1 at R1 oper hours R2 Solar loading operating hours V1 at R2 Display Description time Time Filter runtime Present day runtime of the filter pump Relay1 Relay1 on off Relay2 Relay2 on off 6 3 Functions Adjustment values Display Description DTon Switch on difference DToff Switch off difference poolmax Maximum pool temperature T DTon Delay mIN on Minimu...

Page 10: ...switch off difference TFlow TPool for the solar circuit in Kelvin The switch off difference has to be at least 0 2 K lower than the switch on difference DTon Adjustment of the minimum filter pump runtime in hours The filter pump is switched on for this adjusted filtration period every day The filter runtime ends when the adjusted ending time is reached The minimum filter runtime will also be compl...

Page 11: ... if the adjusted temperature threshold TAbs max is exceeded Adjustable switch on and switch off hysteresis DTAbs max which prevents the controller from switching on and off again because of very small temperature differences Absorber minimum limitation Adjustments Absorbermin Selection Yes No Factory setting No Adjustments TAbs Min Adjustment range 10 90 C Factory setting 10 C Adjustments DTAbs mi...

Page 12: ...n Auto mode During normal operation the relay is set to Auto Language language Selection Deutsch English francais castellano italiano Factory setting Deutsch Adjustment of the menu language Deutsch English fran cais castellano italiano 8 Error indication A possible failure of the pool flow or absorber sensor will be indicated on the display The solar system will be switched off or if already off r...

Page 13: ...4 13 12 DeltaSol Minipool 220 240V VBus 9 10 2 1 A 220 24 0 V T1 25A Operating control lamp off Check the power supply Is it disconnected yes no The fuse of the controller could be blown It can be replaced after the front cover has been removed spare fuse is enclosed in the accessory bag Check the supply line and reconnect it D e lt a S o l MiniPool RESOL 09225 DeltaSol_MiniPool monen indd 13 ...

Page 14: ...or temperature sensors indoor temperature sensors cylindrical clip on sensors and irradiation sensors also as complete sensors with immersion sleeves RESOL ServiceCenter Software The controller data can be read out for visualising and mo nitoring the system state The light version of the software is availabe for free download at www resol com The full version additionally allows easy configuration...

Page 15: ...Notes D e lt a S o l MiniPool RESOL 09225 DeltaSol_MiniPool monen indd 15 ...

Page 16: ...tions microfilms and the storage into electronic systems Editor RESOL Elektronische Regelungen GmbH Important notice We took a lot of care with the texts and drawings of this manual and to the best of our knowledge and consent As faults can never be excluded please note Your own calcu lations and plans under consideration of the current stan dards and guidelines should only be basis for your proje...