background image

CLIMEXEL HEAT PUMPS MANUAL

 

pag. 18 di 18 

www.cpa-piscine.it 

Ver.02

2017-08-04 

 

 

 

 

 

 

 

Le informazioni contenute nel presente documento possono variare a discrezione del redigente, senza preavviso, contestualmente alle modifiche del prodotto in oggetto al presente documento: sarà 

responsibility of the customer when placing the order to verify the persistent correspondence of the product to the informati on sheet. 

 

 Any technical diagrams reproduced in this document have a purely informative value and are not valid for regulatory purposes  

 

All operations must be performed in a workmanlike manner and exclusively by qualified personnel in possession of the requisit es required by current regulations. 

 

It is essential that the installation is carried out by competent and qualified personnel, in possession of the technical req uirements required by the specific regulations on the 

subject. By qualified personnel we mean those people who, due to their training, experience and education, as well as their knowledge of the relevant standards, prescriptions f or 

accident prevention measures and service conditions, have been authorized by the plant safety manager to carry out any necess ary activity and in this being able to know and 

avoid any danger. 

 

This document does not in any way replace the technical documentation relating to the products indicated provided by the manu facturer of the same, to which the installer must 

contact in order to obtain all the technical information not present in the aforementioned document. 

 

The C.P.A. s.r.l. assumes no responsibility for any problems deriving from erroneous interpretation of the text.  

 

The C.P.A. s.r.l. furthermore, it declines all responsibility for possible inaccuracies contained in this manual, if due to printing or transcription errors. 

19.  ELECTRICAL SCHEME

 

Содержание CLIMEXEL Series

Страница 1: ...MANUAL Ver 02 2017 08 04 C P A S R L MANUALE HEAT PUMPS CLIMEXEL SERIES...

Страница 2: ...SPLAY CORRECT WORKING 11 6 DISPLAY SIGNAL OF ANOMALY 11 7 STOP 11 8 SET POINT DISPLAY AND PROGRAMMING 12 9 ECO COMFORT MODE SELECTION 12 10 SETTINGS AND CONTROLS 13 A CHECKING THE FLOW THROUGH THE BY...

Страница 3: ...al to ensure optimal operation Usually the points to be respected are the following The heat pump must be imperatively installed outdoors and a minimum distance must be respected with any type of wall...

Страница 4: ...llation prepare a concrete slab about ten cm thick at least the same size as the base of the machine Installation at height the support and its fixing on the wall must resist the weight of the machine...

Страница 5: ...am of the filter to minimize greasing of the exchanger and upstream of any injection of chemical products for disinfestation and pH regulation provide a space of 1 5 meters of pipes such as minimum to...

Страница 6: ...nded that the heat pump is not moved more than 10 metres away from the swimming pool Beyond a certain length the pipes must be buried at a sufficient depth take into account the risk of ground frost a...

Страница 7: ...ine must be wired via the white connection box located next to the information plate Remove the protective wrapping Remove the 4 plastic screws from the cover of the connection box to release and remo...

Страница 8: ...e Display the inlet and outlet water temperature and the room temperature Display alarms indicate a defrosting cycle The machine s support base must have a very slight slope approx 1 2 towards the cor...

Страница 9: ...ue changes Push and release The value read by the sensor is shown Press and release in programming mode Scroll through the parameters While editing the parameter value changes Push and release Starts...

Страница 10: ...fficient water flow Appears when the compressor is running Appears when the filtration is in series with the heat pump optional Appears when the defrost function is active while the ambient temperatur...

Страница 11: ...18 www cpa piscine it Ver 02 2017 08 04 6 DISPLAY SIGNAL OF ANOMALY 7 STOP Press to stop the pump when it is in cooling mode Press to stop the pump when in heating mode Display con macchina in spegni...

Страница 12: ...he screen Set point selection 1 Press and hold the SET SET key for 3 seconds 2 The current set point is displayed on the screen flashing 3 Use the or keys to select the new setting 4 Save the setting...

Страница 13: ...scina o aumenter con l aumentare della temperatura dell aria ambiente e o diminuir la temperatura dell acqua da piscina To regulate the flow rate of the by pass loop the machine must be operating at f...

Страница 14: ...e air to the heat transfer fluid The heat pumps are equipped with a device that automatically detects the excessive accumulation of ice and triggers the defrost by inversion of the cycle The defrostin...

Страница 15: ...set point correct Value entered correctly Is filtration running The heat pump starts up but the earth leakage circuit breaker trips Is are the earth leakage circuit breaker or thermal magnetic circui...

Страница 16: ...ost cycle correctly o Does the thermodynamic defrosting phase start Acoustic sound change in compressor pitch and partial ice melting o Ice remains on the bottom of the evaporator condensate does not...

Страница 17: ...at least 5 minutes EE EEPROM alarm Loss of date from the thermostat s EEPROM memory Replace in thermostat ACF1 Configuration alarm Incorrect configuration of the thermostat Input and or output temper...

Страница 18: ...the technical requirements required by the specific regulations on the subject By qualified personnel we mean those people who due to their training experience and education as well as their knowledg...

Отзывы: