background image

CLIMEXEL HEAT PUMPS MANUAL

 

pag. 3 di 18 

www.cpa-piscine.it 

Ver.02

2017-08-04 

 

 

 

Attention! The pump must never 

be  lifted  by  the  hydraulic 

connections: risk of damage! 

 

INSTALLATION

 

WARNING!!! 

The heat pump must only be installed by qualified personnel! 

 

WARNING: 

 

Never  lift  the  machine  by  the  hydraulic  fittings,  there  is  the  risk  of  damaging  the 

connection with the titanium exchanger located inside the machine. 

 

heat pump must always be placed in a vertical position, NEVER in a horizontal position 
 

Warranty does not cover damage caused by poor maintenance! 

 

CHOICE OF THE POSITIONING AND INSTALLATION AREA 

 

The positioning and installation of the heat pump are essential to ensure optimal operation. Usually the 
points to be respected are the following: 

 

The  heat  pump  must  be  imperatively  installed  outdoors,  and  a  minimum  distance  must  be 

respected with any type of wall (walls, wooden walls, plant coverings ...) so as not to obstruct 

the circulation of air through the machine. 

 

The air emitted by the fans must not be re-sucked, even partially: for this reason, the machine must 

not  be  installed  in  a  place  confined  by  a  set  of  walls,  even  if  the  distances  indicated  above  are 
respected. 

 

The heat pump must not be directly exposed to prevailing winds. 

 

Model 

M.P.I. 80M 

M.P.I. 100M 

M.P.I. 160M 

M.P.I. 190M 

M.P.I. 190T 

M.P.I. 240M 

M.P.I. 240T 

M.P.I. 320T 

M.P.I. 380T 

Numero di ventole 

Flusso 

d’aria

 [m

3

/h] 

2100 

2100 

3300 

6000 

6000 

6000 

6000 

8400 

8400 

Portata acqua [m

3

/h] 

4<Q <5 

4<Q <5 

4<Q <6 

5<Q <7 

5<Q <7 

8<Q <10 

8<Q <10 

10<Q <12 

10<Q <12 

Содержание CLIMEXEL Series

Страница 1: ...MANUAL Ver 02 2017 08 04 C P A S R L MANUALE HEAT PUMPS CLIMEXEL SERIES...

Страница 2: ...SPLAY CORRECT WORKING 11 6 DISPLAY SIGNAL OF ANOMALY 11 7 STOP 11 8 SET POINT DISPLAY AND PROGRAMMING 12 9 ECO COMFORT MODE SELECTION 12 10 SETTINGS AND CONTROLS 13 A CHECKING THE FLOW THROUGH THE BY...

Страница 3: ...al to ensure optimal operation Usually the points to be respected are the following The heat pump must be imperatively installed outdoors and a minimum distance must be respected with any type of wall...

Страница 4: ...llation prepare a concrete slab about ten cm thick at least the same size as the base of the machine Installation at height the support and its fixing on the wall must resist the weight of the machine...

Страница 5: ...am of the filter to minimize greasing of the exchanger and upstream of any injection of chemical products for disinfestation and pH regulation provide a space of 1 5 meters of pipes such as minimum to...

Страница 6: ...nded that the heat pump is not moved more than 10 metres away from the swimming pool Beyond a certain length the pipes must be buried at a sufficient depth take into account the risk of ground frost a...

Страница 7: ...ine must be wired via the white connection box located next to the information plate Remove the protective wrapping Remove the 4 plastic screws from the cover of the connection box to release and remo...

Страница 8: ...e Display the inlet and outlet water temperature and the room temperature Display alarms indicate a defrosting cycle The machine s support base must have a very slight slope approx 1 2 towards the cor...

Страница 9: ...ue changes Push and release The value read by the sensor is shown Press and release in programming mode Scroll through the parameters While editing the parameter value changes Push and release Starts...

Страница 10: ...fficient water flow Appears when the compressor is running Appears when the filtration is in series with the heat pump optional Appears when the defrost function is active while the ambient temperatur...

Страница 11: ...18 www cpa piscine it Ver 02 2017 08 04 6 DISPLAY SIGNAL OF ANOMALY 7 STOP Press to stop the pump when it is in cooling mode Press to stop the pump when in heating mode Display con macchina in spegni...

Страница 12: ...he screen Set point selection 1 Press and hold the SET SET key for 3 seconds 2 The current set point is displayed on the screen flashing 3 Use the or keys to select the new setting 4 Save the setting...

Страница 13: ...scina o aumenter con l aumentare della temperatura dell aria ambiente e o diminuir la temperatura dell acqua da piscina To regulate the flow rate of the by pass loop the machine must be operating at f...

Страница 14: ...e air to the heat transfer fluid The heat pumps are equipped with a device that automatically detects the excessive accumulation of ice and triggers the defrost by inversion of the cycle The defrostin...

Страница 15: ...set point correct Value entered correctly Is filtration running The heat pump starts up but the earth leakage circuit breaker trips Is are the earth leakage circuit breaker or thermal magnetic circui...

Страница 16: ...ost cycle correctly o Does the thermodynamic defrosting phase start Acoustic sound change in compressor pitch and partial ice melting o Ice remains on the bottom of the evaporator condensate does not...

Страница 17: ...at least 5 minutes EE EEPROM alarm Loss of date from the thermostat s EEPROM memory Replace in thermostat ACF1 Configuration alarm Incorrect configuration of the thermostat Input and or output temper...

Страница 18: ...the technical requirements required by the specific regulations on the subject By qualified personnel we mean those people who due to their training experience and education as well as their knowledg...

Отзывы: