CLIMEXEL HEAT PUMPS MANUAL
pag. 3 di 18
Ver.02
–
2017-08-04
Attention! The pump must never
be lifted by the hydraulic
connections: risk of damage!
INSTALLATION
WARNING!!!
The heat pump must only be installed by qualified personnel!
WARNING:
▪
Never lift the machine by the hydraulic fittings, there is the risk of damaging the
connection with the titanium exchanger located inside the machine.
▪
heat pump must always be placed in a vertical position, NEVER in a horizontal position
Warranty does not cover damage caused by poor maintenance!
CHOICE OF THE POSITIONING AND INSTALLATION AREA
The positioning and installation of the heat pump are essential to ensure optimal operation. Usually the
points to be respected are the following:
▪
The heat pump must be imperatively installed outdoors, and a minimum distance must be
respected with any type of wall (walls, wooden walls, plant coverings ...) so as not to obstruct
the circulation of air through the machine.
▪
The air emitted by the fans must not be re-sucked, even partially: for this reason, the machine must
not be installed in a place confined by a set of walls, even if the distances indicated above are
respected.
▪
The heat pump must not be directly exposed to prevailing winds.
Model
M.P.I. 80M
M.P.I. 100M
M.P.I. 160M
M.P.I. 190M
M.P.I. 190T
M.P.I. 240M
M.P.I. 240T
M.P.I. 320T
M.P.I. 380T
Numero di ventole
1
1
1
2
2
2
2
2
2
Flusso
d’aria
[m
3
/h]
2100
2100
3300
6000
6000
6000
6000
8400
8400
Portata acqua [m
3
/h]
4<Q <5
4<Q <5
4<Q <6
5<Q <7
5<Q <7
8<Q <10
8<Q <10
10<Q <12
10<Q <12