BYD COMPANY LIMITED
Document
Installation Manual and User Manual for BYD
Project No.
\
Code
2M SOP0007540
Edition
13
Page
8 / 19
8
TAB.3 The size of each code
measure
L
W
T
C
Model
Mechanical
load test
(
Front)
)
Mechanical load
test
(
Back
)
BYDxxxPIC/K-36
2008 1002
35
1300
3600Pa
2400Pa
BYDxxxMIC/K-36
BYDxxxPIC/K-39
2166
998
35
1300
3600Pa
2400Pa
BYDxxxMIC/K-39
Remark: A load of 2400Pa for frontal, a load of 1600Pa for back(IEC61215
2016 safety factor 1.5).
During installation of the modules it should be made sure, that all
mounting holes are used for fixation, the number of mounting holes for
each module series is indicated in the table below:
TAB.4 Number of mounting holes for each series of components
Model
measure
n
Model
measure
n
BYDxxxP6C/K-18
4
BYDxxxP6C/K-36
8
BYDxxxM6C/K-18
BYDxxxM6C/K-36
BYDxxxP6C/K-24
8
BYDxxxPHC/K-36
BYDxxxP6C/K-27
BYDxxxMHC/K-36
BYDxxxP6C/K-30
BYDxxxMIC/K-36
BYDxxxM6C/K-30
BYDxxxPIC/K-39
BYDxxxPHC/K-30
BYDxxxMIC/K-39
BYDxxxMHC/K-30
BYDxxxPIC/K-30
BYDxxxMIC/K-30
Installation details:
FIG.5 Diagram of pressure installation under 3600Pa(IEC61215
2016 safety factor 1.5)
1) Aluminum Frame
2) M8 Stainless Bolt M8
3) Flat Stainless Washer
4) Spring Stainless Washer
5) HEX Stainless Nut
3.2.2 Clamping
For clamping of the modules, clamps can be used as in the figure
below, while the clamps must be strong enough to fasten the modules
(the use of stainless steel is recommended), and their structure must
not cover the cells.
A load of 3600Pa for frontal, a load of 1600Pa for