BYD COMPANY LIMITED
Document
Installation Manual and User Manual for BYD
Project No.
\
Code
2M SOP0007540
Edition
13
Page
14 / 22
14
below for installation on the long side of the frame:
FIG.
12 Guide
rail
installation diagram
FIG. 13 The front cannot block the PV
plate and the back cannot block the grounding hole
The installation mode of the half-cell intermediate outgoing module is
recommended the long edge to be parallel the ground; The installation
mode of the half-cell long edge outgoing module is recommended the
short edge to be parallel the ground.
All the mounting ways above are suitable to roof mounting.
And
the
module is considered to be in compliance with IEC61215 when the
module is mounted in the manner specified by the mounting instruction
above.
Tab 6. List of mounting modes with border thickness
Thickness
Installation
50mm
45mm
40mm 35mm
30mm
Refer