Installation details:
FIG.5 Diagram of pressure installation under 3600Pa(IEC61215
2016 safety factor 1.5)
1) Aluminum Frame
2) M8 Stainless Bolt M8
3) Flat Stainless Washer
4) Spring Stainless Washer
5) HEX Stainless Nut
3.2.2 Clamping
For clamping of the modules, clamps can be used as in the
figure below, while the clamps must be strong enough to
fasten the modules (the use of stainless steel is
recommended), and their structure must not cover the cells.
A
load of 3600Pa for frontal, a load of 1600Pa for
back(IEC61215 2016 safety factor 1.5); 2400 Pa wind load
and 5400 Pa snow (IEC61215 2005);
If a module is installed with clamps on a long side of the frame,
“B”
denotes the possible clamping range:
FIG. 6 Installation diagram of four fixtures under pressure of a load of 3600Pa
for frontal, a load of 1600Pa for back(IEC61215 2016 safety factor 1.5).
TAB.5 The dimensions corresponding to fixture installation