Installation Manual V1.0
5. Assembly
5.1.
Wall Mounting
5.1.1.
Selecting the Mounting Location
Requirements for the mounting location:
o The mounting location must not be in a living or office area.
o The mounting location must not block any escape routes.
o The mounting location must be freely and safely accessible at all times without the necessity for
any auxiliary equipment (such as scaffolding or lifting platforms). Non-fulfillment of these criteria may
restrict servicing.
o
The mounting location must be suitable for the weight and dimensions of the Combiner Box.
o
The mounting location must not be exposed to direct solar irradiation.
o
The recommended height of the location is higher than 1.6 meter
s
from the ground.
o
Make sure that the Combiner Box enclosure is not mounted in the path of rainwater.
Requirements for mounting:
o
Mount the Combiner Box in such a way that the connection area is facing downwards.
o The recommended height of the wall box
o
Do not mount the Combiner Box in an inclined position.
5.1.2.
Mounting the Combiner Box
Fire hazard due to wrong choice of mounting location
Under fault conditions electric arcs may occur in the Combiner Box. Electric arcs can cause fires if the
Combiner Box is mounted on flammable materials.
• Do not mount the Combiner Box on flammable construction materials.
• Do not mount the Combiner Box near highly flammable materials.
• Do not mount the Combiner Box in potentially explosive atmospheres.
Danger of crushing if the Combiner Box is dropped
• When mounting the Combiner Box, take the weight of up to 9.7 kg into account.
• Installer should use personal protective equipment.