9 Operator responsibilities
You have purchased a durable and service-friendly product.
However, all technical equipment requires regular servicing to guaran-
tee optimal functioning.
Regular checks performed by the operator are required for the warran-
ty and proper functioning of the unit. The unit must be inspected regu-
larly or, at the latest, every 2 months depending on service and opera-
ting conditions.
On a regular basis, find out about the quality/pressure ratio of the wa-
ter to be treated. If the water quality changes, the settings may need to
be changed. Consult a specialist if this is the case.
9.1 Checks
The operator must perform the following checks regularly to guarantee
that the unit functions properly.
Check the network pressure/flow pressure
Once a week
Check/refill regenerative
According to use
Check brine containers for soiling
Every 2 months
Check for leaks, visual inspection
Every 2 months
Functional test/control unit displays
Every 2 months
Checking the water hardness
The hardness of untreated water entering the unit as well as the set
hardness of the blended water must be checked, logged at regular in-
tervals and corrected if need be (see Safety instructions and Starting
the unit).
Checking the hardness of untreated water
Residential / Commercial buildings
Monthly
Industry / Boiler / Air conditioning
Once a week
Pre-treatment for membrane processes
Once a week
Checking the hardness of softened water / blended water
Residential / Commercial buildings
Monthly
Industrial
Depending on the requirement, daily for softened water
Boiler/air conditioning
Daily
Pre-treatment for membrane processes
Daily
Option
A Testomat F-BOB automatic hardness tester can be used to check the
hardness of the softened water / blended water and monitored via CIC.
Order no.: 11987
10 Warranty
If the product malfunctions during the warranty period, please contact
your contract partner, the installation company, and indicate the mo-
del type and production number (see specifications or the type plate
on the unit).
Non-compliance with the installation conditions and the operator respon-
sibilities voids the warranty.
The wearing parts defined in the “Operator responsibilities” section and
the consequences of failing to replace these parts on time are not co-
vered by the 2-year legal warranty.
BWT assumes no liability in the event that the unit fails or if the capa-
city becomes deficient due to incorrect material selection/combination,
floating corrosion products or iron and manganese deposits, or any re-
sulting damage thereof.
The use of regenerative that does not comply with DIN EN 973 type A
voids the warranty.
9.2 Maintenance
The replacement of wearing parts within the prescribed maintenance
intervals is also required for the warranty and proper functioning of the
unit. The unit must be serviced once a year. Communal units must be
serviced twice a year.
We recommend that you enter into a maintenance agreement with your
fitter or the after-sales service department.
Maintenance and wearing parts
Hygienic cleaning of the brine container at least
Once a year
Inspect regeneration block
Once a year
Inspect non-return valve
Once a year
Inspect brine valve
Once a year
Inspect electrolysis cell
Once a year
Check low-salt level
Once a year
Charge Soft-Control battery
Once a year
Main membrane
Every 3 years
Electrolysis cell
Every 3 years
Regeneration block non-return valve
Every 3 years
Waste water valves
Every 3 years
Regeneration block
Every 5 years
Gauge slide
Every 5 years
Water meter cover
Every 5 years
Dilution unit
Every 5 years
Connection hoses
Every 5 years
Brine valve
Every 5 years
Brine pipeline
Every 5 years
Waste water hose
Every 5 years
Container
Every 10 years