EN
40
7.2 Setting the hardness of water
Press the Browse button
Set the cursor to Settings
Press OK
You can make the following settings here:
Move the arrow horizontally to the required field.
The field becomes negative.
The value or the unit can be changed with the arrow up/down arrows.
The softened water supply can be displayed in liters, m
3
or US-gallons.
Water hardness can be displayed in °dH, °fH, °eH, CaCo3 (ppm).
Hardness of untreated water IN
You must set the hardness of the untreated water measured locally here.
Hardness of blended water OUT
The 0 may not be changed here. The water meter only counts water
softened to 0° dH.
The values changed are saved immediately.
Press the Browse button
Set the cursor to Manual regeneration
and press the OK to confirm.
The unit is regenerating.
You can view any procedure as a diagram with progressing time by pres-
sing Browse twice.
As this happens each stage of the regeneration process is displayed.
The regeneration process lasts between 28 and 52 minutes depending
on the unit. The brine container fills up (see brine preparation)
The programming necessary for starting the unit is complete.
Liter
CaCo3
IN 25 CaCo3
OUT 0
CaCo3
Note! Do not change 0!
Содержание Rondomat Duo-DVGW 10
Страница 10: ...DE 10 6 1 Klemmenpläne Rondomat Duo DVGW 2 3 und Rondomat Duo Industrie 2 3 6 10 ...
Страница 48: ...FR 48 ...
Страница 70: ...70 ...