Remove mains plug.
Fasten the DVGW electrolysis unit to the back of the Soft Control console using the supplied screws and fastenings.
Connect wire A to the valve block and to the electrolysis cell using plugs.
Connect wire B to the terminals on the Soft Control controller.
The mains plug of the Soft Control controller can be removed and the cable can be connected to terminals L, N of the DVGW
electrolysis unit.