![BWT Perla Hybrid Скачать руководство пользователя страница 65](http://html1.mh-extra.com/html/bwt/perla-hybrid/perla-hybrid_installation-and-operating-manual_2836817065.webp)
65
EN
13 3 1 Inspection activities
The scope of required inspection activities is more limited if your product is registered with BWT and you
use the available options (see table):
●
BWT Best Water Home app
●
Download, check and archive device documentation from the app
This is the only way to directly detect and act on necessary actions or mechanical/hydraulic/electrical
problems.
Inspection activities
Interval
Instruction
for products
WITHOUT
online regis-
tration
Instruction
for products
WITH online
registration
Check/refill regenerative
According to use
Required
Required
Check brine containers for soiling
Every 2 months
Required
Required
Check for leaks, visual inspection
Every 2 months
Required
Required
Functional test/control unit display
Every 2 months
Required
Not
required
Test regenerative consumption depending
on the treated water
Every 2 months
Required
Not
required
Check the setting of the regeneration waste
water system
Every 2 months
Required
Required
Check the counting function of the water
meter
Every 2 months
Required
Not
required
Test the regeneration process
Every 2 months
Required
Not
required
Test the consumption of the mineral
substance based on the treated water
Every 2 months
Required
Not
required
Clean the brine container and the internal
surfaces that come into contact with water
Every 6 months
Required
Required