Device configuration
Depending on your product and the installed soft-
ware, additional device settings are possible. You
can activate/deactivate these settings as required.
►
Press the checkbox(es) to activate or deactivate
functions.
AQA Stop Sensor
If the product’s floor sensor detects water on the
floor, the water supply in the direction of flow behind
the product is shut off and a warning is issued. The
floor sensor only responds to drinking water (mini
-
mum conductivity of 500 µS/cm).
►Fix the cause of moisture on the floor.
►Dry the floor and the sensor.
►
Acknowledge the message (see chapter
AQA Stop Litre
To minimise water damage, the control valve can
shut off the water supply downstream of the product.
To do so, specify the water volume at which it should
be shut off following continuous flow. Select this
water volume so that your usual water consumption
is not affected.
►
Press the number to change the water volume.
If the
AQA STOP LITRE
function has been triggered:
►
Acknowledge the message (see chapter
If a large amount of water is tapped without in-
terruption, you can switch off the
AQA STOP LITRE
function for a short period of time by deactivating
the checkbox.