BÜTTNER ELEKTRONIK – Batterie-Control-Booster MT BCB 30/30, MT BCB 40/40, MT BCB 60/40
20
LiFePO
4
13.9 V:
Charging program for Dometic eStore - LiFePO
4
-batteries with integrated
BMS
(Check other LiFePO
4
batteries for suitability of 13.9 V charging voltage and only operate
completely with their own BMS and the required protective circuit !)
U1 Absorption voltage: 13.90 V (0,5 – 1h)
U2 Float voltage: 13.90 V (24 h)
U3 Storage voltage: 13.50 V cont.
LiFePO
4
14.2 V:
Charging program for Victron / Transwatt TH12/xxx - LiFePO
4
-batteries
with integrated BMS
(Check other LiFePO
4
batteries for suitability of 14.2 V charging voltage and only operate
completely with their own BMS and the required protective circuit!)
U1 Absorption voltage: 14.20 V (0,5 h)
U2 Float voltage: 13.60 V (24 h)
U3 Storage voltage: 13.40 V cont.
LiFePO
4
14.4 V:
Charging program BÜTTNER ELEKTRONIK LiFePO
4
-Professional batteries,
SuperB SB12VxxE, GNB/Exide SL12xxxHC with integrated BMS.
(Check other LiFePO
4
batteries for suitability of 14.4 V charging voltage and only operate
completely with their own BMS and the required protective circuit!)
U1 Absorption voltage: 14.40 V (0,3 h – 1h)
U2 Float voltage: 13.60 V (24 h)
U3 Storage voltage: 13.50 V cont.
LiFePO
4
14.6 V:
Charging program RELION Lithium Ion Battery with integrated BMS.
(Check other LiFePO
4
batteries for suitability of 14.6 V charging voltage and only operate
completely with their own BMS and the required protective circuit!)
U1 Absorption voltage: 14.6 0V (0.3 h)
U2 Float voltage: 13.80 V (24h)
U3 Storage voltage: 13.50 V cont.
Note when using a LiFePO
4
battery
i
• Only operate the battery completely with its own BMS (Battery Management System)
and prescribed protective circuit!
• It is essential to observe the battery manufacturer's charging instructions!
• Operation of the device on a LiFePO
4
battery without a BMS and without cell balancing
and protective circuitry is not permitted!
• To protect the battery, the battery temperature sensor must be connected to the battery
terminal (minus pole) and to the device, otherwise the device has no function (see also
section 4.7. Troubleshooting)
• If possible, install the battery preferably, that temperatures can be kept above 0°C.