6 | Commissioning
22 | 40
Instruction Manual MINK MV 0500-0600 B_EN_en
6.1.4
Pressure Control
NOTICE
Changing of any other parameters than described below.
Risk of damage to the machine!
●
Do not change any other parameter than described below.
NOTE: VFD parameter settings for pressure control
–
MV 0500 B - T434215938
–
MV 0600 B - T434215939
Piping and Instrumentation Diagram
PSA
1
P
M
CPL
MOT
PSA
2
P
OUT
VFD*
NRV
*also termed VSD
Process
process
(included)
inlet gas
1
2
3
4
5
6
7
Description
1
Non-return valve
2
Pressure transmitter 1
3
Pressure transmitter 2
4
Variable-frequency drive
5
Motor
6
Coupling
7
Discharge connection