11 | Troubleshooting
32 | 40
Instruction Manual MINK MV 0500-0600 B_EN_en
11
Troubleshooting
DANGER
Live wires.
Risk of electrical shock.
●
Electrical installation work must only be executed by qualified personnel.
CAUTION
Hot surface.
Risk of burns!
●
Prior to any action requiring touching the machine, let the machine cool down first.
VRE
CPL
IS
Description
IS
Inlet screen
VRE
Vacuum relief valve
CPL
Coupling
Problem
Possible Cause
Remedy
The machine does not start.
The variable-frequency drive
(VFD) is not supplied with the
correct voltage.
●
Check the power supply.
The motor or the variable
frequency drive (VFD) is
defective.
●
Replace the motor or the
variable-frequency drive
(VFD).
The coupling (CPL) is defective.
●
Replace the coupling (CPL).