Maintenance | 7
0870221625_MV0040-0080D_-0000_IM_en_MD
19 / 32
7.1 Maintenance Schedule
The maintenance intervals depend very much on the individual operating conditions.
The intervals given below are considered as starting values which should be
shortened or extended as appropriate. Particularly harsh applications or heavy duty
operation, such as high dust loads in the environment or in the process gas, other
contamination or ingress of process material, can make it necessary to shorten the
maintenance intervals significantly.
Interval
Maintenance work
Monthly
• Check the inlet filter cartridge of the condensate
reservoir, replace if necessary.
In case of an inlet filter being installed:
• Check the inlet filter cartridge, replace if neces-
sary.
Every 3 months
• Check the oil level, see
Every 6 months
• Clean the machine from dust and dirt.
Every 8000 hours, at the least
once a year
• Change the oil.
• Reset the maintenance counter via terminal 14 (Di-
gital In 4) of the control unit.
• Drain the condensate reservoir.
Every 6 years
• Have a major overhaul on the machine (contact
Busch).
7.2 Oil Level Inspection
• Shut down the machine.
• When the machine is stopped, wait 1 minute before checking the oil level.
The oil level should stay constant over the lifetime of the oil. If the level does fall, this
indicates a leak and the machine requires repair.
.