Commissioning | 6
0870221625_MV0040-0080D_-0000_IM_en_MD
15 / 32
6
Commissioning
NOTICE
Lubricating a dry running machine (compression chamber).
Risk of damage to the machine!
• Do not lubricate the compression chamber of the machine with oil or grease.
CAUTION
During operation the surface of the machine may reach temperatures of more than
70°C.
Risk of burns!
• Avoid contact with the machine during and directly after operation.
CAUTION
Noise of running machine.
Risk of damage to hearing!
If persons are present in the vicinity of a non noise insulated machine over extended
periods:
• Make sure that ear protection is being used.
• Make sure that the installation conditions (see
met.
• Switch on the machine.
NOTICE
Frequent starts and stops by connecting and disconnecting from the power supply.
Risk of damage to the machine!
Starting the machine by connecting and disconnecting the power supply is permitted
max. 1x per minute. Between disconnecting and connecting at least 10 seconds must
have been passed. If the process requires more frequent starts/stops of the machine:
• Use the digital start signal.
• Maximum permissible number of starts by using the digital signal: unlimited
As soon as the machine is operated under normal operating conditions:
• Measure the motor current and record it as reference for future maintenance
and troubleshooting work.