Installations- und Betriebsanleitung Mink MI 1252 BV
Installation and operating instructions Mink MI 1252 BV
Manuel d'installation et de maintenance Mink MI 1252 BV

10

Dr.-Ing. K. Busch GmbH
Schauinslandstraße 1
D 79689 Maulburg

In compliance with the EC Machinery Directive
98/ 37/ EC, appendix II A it is confirmed by

in Übereinstimmung mit der EG-Maschinen-
richtlinie i. d. F. 91/ 368/ EWG und 98/ 37/ EG,
der EG-Niederspannungsrichtlinie 73/ 23/ EWG,
der EMV-Richtlinie 89/336/EWG, sowie den
nachfolgend genannten Normen und Vorschrif-
ten hergestellt worden ist.

is manufactured in accordance to EC Machinery
Directive 91/ 368/ EEC and 98/ 37/ EC, EC low
voltage standard 73/ 23/ EEC, EC standard for
electromagnetic tolerance 89/336/EEC and all
standards listed on the reverse side.

est fabriqué conformément à la Directive Ma-
chines CE, selon la version 91/ 368/ CEE et 98/
37/ CE, la Directive Basse Tension CE 73/ 23/
CEE, CE conformité électromagnétique 89/336/
CEE‚ de même que selon les normes et pres-
criptions indiquées ci-après.

that following

atteste que la (le)

dass nachfolgend beschriebene

EG Konformitätserklärung
EC Declaration of Conformity
CE Déclaration de Conformité

Mit dieser Konformitätserklärung im Sinne der
EG-Maschinenrichtlinie 98/ 37/ EG Anhang II A
erklärt die Firma

Avec cette déclaration de conformité dans le
sens de la Directive Machines 98/ 37/ CE,
annexe II A, l'entreprise

Dr.-Ing. Karl Busch

Geschäftsführer
General director

Directeur général

Norm
Norm
Norme

EN 292, 1
EN 292, 2

EN 294

EN 60204

DIN 1012, 1
DIN 1012, 2

EN 50081, 1
EN 50081, 2

EN 50082, 1
EN 50082, 2

Harmonisierte Normen/ harmonized normes/ normes harmonisées

Nationale Normen/ national normes/ normes nationales

DIN 45635, 13

Geräuschmessung an Maschinen (Verdränger-, Turbo- und Strahlverdichter)
Measurement of airborne noise emitted by machines (Displacement-, turbo- and jet-compressors)
Mesure sonore sur les machines (compresseur volumétrique, centrifuge et faisceau)

Titel der Norm
Title of the norm
Titre de la norme

Sicherheit von Maschinen: Grundbegriffe, allgemeine Gestaltungsleitsätze; Teil 1 und 2
Safety of machinery: Basic concepts, general principles for design; Part 1 and 2
Sécurité des machines; Notions fondamentales, principes généraux de conception; Partie 1 et 2

Sicherheit von Maschinen: Sicherheitsabstände gegen das Erreichen von Gefahrenstellen mit den oberen Gliedmaßen
Safety of machinery: Safety distance to prevent danger zones being reached by the upper limbs
Sécurité des machines, distances de sécurité pour empêcher que les zones de danger soient atteintes par les membres
supérieurs

Elektrische Ausrüstung von Maschinen
Electrical equipment of machines
Equipement électrique des machines

Kompressoren und Vakuumpumpen; Sicherheitsanforderungen - Teil 1 und 2
Compressors and vacuum pumps; Safety requirements; Part 1 and 2
Compresseurs et pompes à vide; Exigences en matière de sécurité; Partie 1 et 2

Elekromagnetische Verträglichkeit; Fachgrundnorm Störaussendung; Teil 1 und 2
Electromagnetic compatibility: Generic emission standard; Part 1 and 2
Compatibilité électromagnetique: Norme générique émission; Partie 1 et 2

Elekromagnetische Verträglichkeit; Fachgrundnorm Störfestigkeit; Teil 1 und 2
Electromagnetic compatibility; Generic immunity standard; Part 1 and 2
Compatibilité électromagnetique; Norme générique immunité; Partie 1 et 2

Vakuumpumpe

Mink MI 1252 BV

vacuum pump

Mink MI 1252 BV

pompe à vide

Mink MI 1252 BV

Содержание Mink MI 1252 BV

Страница 1: ...en Mink MI 1252 BV Rotary Lobe Vacuum Pumps Mink MI 1252 BV Pompes à Vide à Lobes Rotatifs Mink MI 1252 BV Installations und Betriebsanleitung Installation and operating instructions Manuel d installation et de maintenance ...

Страница 2: ...iftig noch explosiv sind Die Temperatur der angesaug ten Gase sollte 40 C nicht überschreiten Wen den Sie sich im Zweifelsfall an das Herstel lerwerk Safety This Mink rotary lobe vacuum pump has been manufactured according to the technical stan dards and safety regulations If not installed pro perly or not used as directed dangerous situa tions or damage might occur Application Mink rotary lobe va...

Страница 3: ... of wear Two rotary lobes are rotating in opposite directions within a cylinder inducting and compressing a gas me dium The shape of the lobe is such that a small gauged clearance is maintained between the lobe tips and the cylinder walls and also at the adjacent lobe surfaces As the lobes rotate con stantly gas is sucked in compressed and dis charged under pressure Mink rotary lobe vacuum pumps a...

Страница 4: ...nden 4 Bei Bedarf ist ein Luftfilter für die Ansaugluft anzuschließen Start up It is essential to observe the following in structionsstepbysteptoensureasafestart up Start up may only be carried out by trained specialists 1 Setting up Thepumpmustbesetupormountedhorizontally onaflatsurface Specialmountingisnotrequired as the pump can be mounted with screws via the threads of the rubber feet of the p...

Страница 5: ...lation of the vacuum pump theelectricalconnectionmustbeequipped with cable guides that have the function of trac tion relief 4 The driving motor is equipped with a PTC thermistor that can be connected to a contactor and integrated into the control 5 To check the direction of rotation of the pump flick the ON OFF switch In case of incorrect di rection reverse the polarity of any two of the electric...

Страница 6: ...rden Im Sauganschluss befindet sich ein Schutzsieb Dieses Schutzsieb muss ebenfalls in regelmä ßigen Abständen gereinigt werden HierzumussderSaugflanschabgeschaubtwer den Andere Wartungsarbeiten auch im Verdich tungsraum sindnichtdurchzuführen Wennauf Maintenance The vacuum pump must be switched off and secured against accidental switch on for all maintenance Cleaning of inlet filter The inlet fil...

Страница 7: ...resserrer les ècrous fixés sur les tiges filetées au niveau de la bride d aspiration et des flasques avec une clè dynamométrique réglée à 30 Nm Resserrer la vis de fixation du ventilateur avec un couple de serrage de 20 Nm Le carter des pignons de synchronisation est totalement séparé du reste de la pompe Les pignons sont lubrifiés avec l huile ISO VG 100 Cependant il faut vérifier le niveau toute...

Страница 8: ...ung Mink MI 1252 BV Installation and operating instructions Mink MI 1252 BV Manuel d installation et de maintenance Mink MI 1252 BV 7 MI 1252 BV 192 196 64 42 191 104 46 510 20 171 104 100 4 16 174 173 180 701 255 253 701 81 77 72 132 ...

Страница 9: ...t d huile Dichtring 81 Sealing ring Joint Buchse 100 Sleeve Coussinet Kolbenring 104 Piston ring Segment de piston Buchse 132 Sleeve Coussinet Buchse 171 Sleeve Coussinet O Ring 173 O ring Joint torique Wellendichtring 174 Shaft seal Joint d arbre Zylinderrollenlager 180 Roller bearing Roulement à rouleaux cyl O Ring 191 O ring Joint torique Innenring 192 Sleeve Portée axe rotor Wellendichtring 19...

Страница 10: ...eals Pochette de joints Beschreibung Description Description bestehend aus dem Dichtungssatz und sämtlichen Verschleißteilen consisting of seal set and all wearing parts comporte tous les joints et pièces d usure bestehend aus allen notwendigen Dichtungen consistixng of all necessary seals comporte tous les joints nécessaires MI 1252 BV 0945 127 054 0945 118 817 0945 127 055 Zubehör Accessories Ac...

Страница 11: ...rmes normes harmonisées Nationale Normen national normes normes nationales DIN 45635 13 Geräuschmessung an Maschinen Verdränger Turbo und Strahlverdichter Measurement of airborne noise emitted by machines Displacement turbo and jet compressors Mesure sonore sur les machines compresseur volumétrique centrifuge et faisceau Titel der Norm Title of the norm Titre de la norme Sicherheit von Maschinen G...

Страница 12: ...dustry Busch Au cœur de l industrie dans le monde entier Technische Änderungen vorbehalten Technical changes reserved Sujet à modifications techniques Dr Ing K Busch GmbH Postfach 1251 D 79689 Maulburg Telefon 07622 681 0 Telefax 07622 5484 http www busch de Amsterdam Barcelona Basel Birmingham Brussels Copenhagen Dublin Gothenburg Helsinki Istanbul Kuala Lumpur Melbourne Milan Montreal Moscow New...

Отзывы: