Removal from service
Temporary removal from service
l
Prior to disconnecting inlet and outlet pipes as well as cooling
water pipes, make sure that all piping is vented to atmospheric
pressure
Recommissioning
l
Make sure that all gaskets, plugs or adhesive tapes have been
removed
l
Start the vacuum pump as described in the chapter “Installation
and Commissioning”
Dismantling and Disposal of the
vacuum pump
DANGER
In case the vacuum pump has conveyed gases that have been
contaminated with harmful foreign material which are harmful to
health, the oil and the condensates will also be contaminated with
harmful foreign material.
These foreign materials can infiltrate the pores, recesses and other
internal spaces of the vacuum pump.
Danger to health during dismantling of the vacuum pump.
Danger to the environment.
During dismantling of the vacuum pump protective equipment and
clothing must be worn.
The vacuum pump must be decontaminated prior to disposal.
Prior to shipping, the vacuum pump must imperatively be
decontaminated and the degree of contamination must be
documented in a declaration of decontamination (“Declaration of
Decontamination”), which can be downloaded from
www.buschvacuum.com.
Used oil and condensates must be disposed of separately in
compliance with applicable environmental regulations.
When the vacuum pump comes to the end of its life:
–
it must be decontaminated
CAUTION
Only authorised personnel may carry out dismantling work on the
vacuum pump. Before work begins, the operator of the vacuum
pump must fill in a form or a “Declaration of Decontamination” that
provides information on possible dangers and appropriate measures.
If this form has not been filled in completely and signed, the
vacuum pump may not be dismantled.
–
drain the oil
u
dispose of the used oil in compliance with applicable
environmental regulations
–
drain the cooling liquid
u
dispose of the cooling liquid in compliance with applicable
environmental regulations
–
dismantle the vacuum pump
CAUTION
During dismantling of the vacuum pump protective equipment and
clothing must be worn.
u
dispose of the vacuum pump as scrap metal
–
dispose of the different components of the pump in compliance
with applicable regulations
Removal from service
Page 17