AIM-50™ Installation Manual
−
Double Ceiling Version 5000147 A01 5
Support and Anchorage
To prevent sway and provide proper support of the light, the ceiling mount must be attached to a
structurally-sound ceiling. Most ceilings will require additional reinforcing to hold the light. It is
the responsibility of the customer and the installing contractor to provide the safe reinforcement
needed to meet local and state building codes of each installation. A typical reinforcement consists
of a ¼” steel plate, the bottom surface of which is flush with the inside surface of the finished
ceiling (e.g., acoustical tile) and connected firmly to the structural ceiling. Sway braces (e.g., made
of angle iron) are recommended when there is more than 12” between the structural and finished
ceilings. Make certain the installed plate is level, or the arm(s) may “drift”.
Equipment anchorage
diagrams are supplied with these instructions to help with the installation (see page 19). The
diagrams were prepared by a California-licensed Structural Engineer. If the lights are installed
accordingly, the systems will meet requirements of the State Seismic Codes.
Mounting Height
The proper height of the light should be set by the end user. This depends on the ceiling height, the
height of the examination tables, types of procedures and the user’s preferences. (See Figure 1 on
page 6.) Due to the large vertical range of the light head (Approx. 41 in / 1040 mm), the standard
16 in down tube will fit most normal ceiling heights. The following table gives some
recommendations and shows the range of the light with the different length down tubes.
Ceiling height
Down tube
Pivot point
1
Lower limit
Light head
Higher limit
Light head
8.0 ft (96 in)
2438 mm
Standard 12 in
2
5 ft-8 in
1633 mm
3 ft-6 in
975 mm
7 ft-0 in
2030 mm
8.5 ft (102 in)
2591 mm
Standard 16 in
5 ft-10 in
1786 mm
3 ft-8 in
1128 mm
7 ft-2 in
2183 mm
9.0 ft (108in)
2743 mm
Standard 16 in
6 ft-4 in
1938 mm
4 ft-2 in
1280 mm
7 ft-8 in
2335 mm
10.0 ft (120in)
3048 mm
Standard 16 in
7 ft-4 in
2243 mm
5 ft-2 in
1585 mm
8 ft-8 in
2640 mm
20 in
3
7 ft-0 in
2141 mm
4 ft-10 in
1483 mm
8 ft-4 in
2538 mm
11.0 ft (132in)
3353 mm
42 in
3
6 ft-2 in
1887 mm
4 ft-0 in
1229 mm
7 ft-6 in
2284 mm
12.0 ft (144in)
3658 mm
42 in
3
7 ft-2 in
2192 mm
5 ft-0 in
1534 mm
8 ft-6 in
2589 mm
1
Distance from the floor to the pivot point of the spring arm.
2
Cut the standard down tube (from the top) and drill three new holes. See instructions on page 17
3
Contact Burton to obtain a 20” or a 42” Down Tube.