TECHNICAL PASSPORT INSTALLATION and OPERATION MANUAL
Recommended approximate dimensions of firewood:
Type of firewood
А, cm
8 - 10
7 - 9
5
B, cm
12 - 15
13 - 16
20
3. Combustion of disproportionate firewood:
3.1.
Loading of big and disproportionate firewood
Place disproportionate firewood upon an already stacked standard size firewood
at upper part of boiler chamber
3.2.
Loading of small brushwood, pieces of wood and joiner waste.
We recommend first to arrange standard sized firewood /at least 3 lines/ and
then stack all the little pieces of wood and disproportionately on them. Stack the
firewood tight inside with least possible air gaps.
Remember the rule: Smallest and fine pieces of wood should be placed last!
3.3.
Never load small brushwood, pieces of wood and joiner waste in the lower
part of chamber! Prohibited the burning of plastics and other paper packaging.
This can affect to blockage of boiler.
Prohibited the burning of flammable substances or mixtures: diesel, gasoline,
gunpowder, turpentine, paint and the like. Danger of explosion.
Bottom chamber door as well as all inspection
openings must be closed and sealed. From the control
menu select „Ignition” mode. The flue damper opens
to ignite the boiler. In this position the flue gases will
be suctioned out through the topmost part of the
combustion chamber and then with the help of self-
igniting additive and saturated kindling the firing of
the wood is started. Once you get live embers, top-up
the boiler fully with wood, close the flue damper and
then the boiler will gradually enter into normal mode
of operation.
PB - boiler
А - closed
В - open
1.
Pull the lever (В)
2. Open boiler door
3. Load fuel
4. Close boiler door
5. Return the lever back in position
(А)
Diagram 7
*
Do not open the flue damper during
boiler operation! Maintain operating
temperature between 70°C and 80°C.
8.2. Cleaning of the boiler
8.2.1. Cleaning and maintenance by customer.
*
Caution! Hot surfaces.
Before cleaning the boiler, make sure the
fire in it has died out and the boiler has
cooled down.
- Exploitation of the boiler and the type of used
fuel determine how often have to clean the boiler
residues from the combustion process.
- We recommend cleaning the ashes from the upper
chamber of the boiler to be done every 3-4 days
/
Diagram 5
/. In the case where ashes has reached
faster the level of primary air openings, then ashes
must be cleaned immediately. Do not let the ashes
clog these holes.
- The ash accumulates in lower chamber as well. Clean
ash when its level reaches
1/3
of lower chamber
volume /
Diagram 8/
. Uncleaned ash aff ects boiler
operation.