36
TECHNICAL PASSPORT. INSTALLATION and OPERATION MANUAL
TECHNICAL PASSPORT. INSTALLATION and OPERATION MANUAL
TECHNICAL PASSPORT. INSTALLATION and OPERATION MANUAL
TECHNICAL PASSPORT. INSTALLATION and OPERATION MANUAL
navigation arrows.
Quiet Mode menu.
Setting the time interval
when
self-cleaning
system of burner is OFF.
For example: from
22:00 to 06:00
. Check
mark in the box activates Quiet Mode.
10.3.3. Ignition First Feed
Ignition First Feed
25 sec
In this submenu you
can set the number of
attempts (
Retries
) to
ignite the burner and
the time of the initial feed portion of
pellets (
Feed
).
Select the desired option using the
navigation arrows. Use the „
Enter
” button
to open the next parameter.
10.3.4. Cycle setup
From this submenu you
can set:
-
Heater
– the runtime
for the electric ignition
heater
-
Fan B/E
– the runtimes and power
levels of the main burner fan
(FanB)
and
the exhaust gas fan of boiler
(FanE)
in
the process of kindling the initial dose of
pellets.
Operation principle:
After the feed-in of
the initial dose of pellets the heater will
work for
3
min
, then for another
2
min
period parallel to the heater will start the
burner fan
(FanB)
and the exhaust-gas fan
(FanE)
, respectively at
15 %
and
40 %
of
their rated power (exact parameters listed
on p. 41).
If after this period of time the exhaust
gas sensor has not reported a rise in the
exhaust gas temperature, the controller
will shift on to the Unfolding Setup menu.
Through the navigation keys you set the
desired value. Using the button "
Enter
"
you can navigate to the next parameter.
Unfolding Setup
Feed
4 sec
Pause 30 sec
Cycles 10
Unfolding Menu Setup.
Use to set the values
for:
• Feeding of pellets –
Feed;
• Pause time – Pause;
• Number of cycles – Cycles.
From this menu you can also set the
number of cycles and time for feeding
the pellets during ignition mode, while
the temperature of exhaust gases has not
risen. This step is executed in order to
progressively secure a stable combustion.
05
o
From this menu you can
make adjustment of the
temperature difference
at which the boiler
would
shift
from
maximum to minimum power.
Example:
When
the
maximum
temperature Is set at
85°C
the boiler will
shift from maximum to minimum power
once the temperature drops to
80°C
.
10.3.5. Burn Level
In this submenu you can
adjust the performance
of the main operation
mode –
Maximum
Burner
Output
. You can change the pellet feed
quantity
(Feed)
, the peelet feed time
interval
(Cycle)
and the fan operation
power level in percentages
(FAN B/E
).
Example:
At a set period of
20
seconds.
the auger will feed pellets to the burner
for
7
seconds, and stay idle for
17
seconds.
Select the desired option using the
navigation arrows. Use the „
Enter
” button
to open the next parameter.
In this submenu you can
adjust the criteria for
minimum boiler power