Burn Tech GBVS 39/44/49 Скачать руководство пользователя страница 7

5

Product Overview

Introduction

Thank you for choosing Burntech® Fireplace Solutions.

Rest  assured  our  products  have  been  tested  for  safety  and 

durability for many years when properly installed by following 

this manual completely.

Product Overview

Burntech® Fireplaces are designed as factory-built blocks to 

be  assembled  on-site. These  fireplaces  may  be  installed  on 

either combustible or non-combustible floors. In order to func

-

tion, the system requires a 10” B-vent chimney.

The main components of your 

Burntech®

 Fireplace are:

Burntech® Firebox and Smoke Dome

Gas burner, logs and control system 

(sold seperately)

B-vent

 Chimney Pipe(Sold Seperately)

The main categories of the installation of your 

Burntech®

 

Fireplace are:

C

learance to combustibles

Familiarity with all the components for the installation

Foundation strength of your 

Burntech®  fireplace

Chimney system measurements

Set up and use of the gas burner system.

Choice of materials and craftsmanship in fireplace and hearth 

finishing.

Figure 4 - Typical Installations

Internal

Wall

Installation

Corner 

Installation

Flush

Installation

Full 

Projection 

Installation

Note that each of these topics will be covered in detail and that 

the installer is expected to understand each phase completely 

before going on to subsequent instructions. 

Attention

: Be advised that all the illustrations in this manual 

are for general reference only. Do not scale drawings. Actual 

design elements will vary from case to case. Pay attention to 

specified minimum clearances to combustibles.

WARNING!

 Under no circumstances should you allow children 

to remain unattended while a fire is burning in the  fireplace! Be 

sure to keep all objects – furniture, drapes, rugs, etc. at least 

48” (48 inches) away from the opening of the fireplace!

Attention

: You may need a residential building permit to install 

a Burntech® Fireplace. Consult local jurisdictions before you 

get started

!

 The  Burntech®  gas  fireplace  is  not  designed  to  serve  as  a 

primary heat source, rather, the fireplace was expressly created 

as a supplemental source of heat. This unit is designed for use 

with the provided gas burner and approved logs only. 

Testing and listing for the Burntech® gas fireplace has been 

undertaken by PFS Test Laboratories, Inc. to ANSI Z21.50. 

Under no circumstances should the Burntech® gas fireplace be 

considered for other than in-residence buildings of conventional 

construction. 

These components make up the Burntech® gas fireplace and 

in the following pages, you will learn how they work together 

to create an exceptional unit that will give years of service and 

pleasure! 

40 5/8

"

4 3/8"

7 3/8"

A/2

11"

28

"

21"

23"

C
B

4 1/4"

A

32 7/8

"

63-1/2”

D

ø

4” OUTSIDE

 AIR

 

ACCESS - CAN 

BE INST

ALLED 

ON

 T

HE LEFT

 

SIDE ALS

O

Figure 5

Overall Dimensions Burntech® Fireplaces

Model

A

B

C

D

GBVS39

43”

39”

30-1/4”

27-3/4”

GBVS44

48”

44”

35-1/4”

32-3/4”

GBVS49

53”

49”

40-1/4”

37-3/4”

Содержание GBVS 39/44/49

Страница 1: ...0 standard Solid fuels shall not be burned in this fireplace This appliance must be vented vertically through the roof This appliance is not for installation in manufactured or mobile homes The instal...

Страница 2: ...THIS PAGE INTENTIONALLY LEFT BLANK...

Страница 3: ...YPE DO NOT REMOVE THIS LABEL See Burntech Installation Operating Instructions for this model Contact local building officials about restrictions and installation specifications in your area THIS FIREP...

Страница 4: ...ponents Warning Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this appliance may result in property damage or personal injury...

Страница 5: ...DESCRIPTION QTY 1 TFS39 1 TFS44 1 TFS49 1 HEARTH Left or Right 2 2 TFS39 2 TFS44 2 TFS49 2 REAR WALL 3 3 TFS39 3 TFS44 3 TFS49 3 SIDE WALL 7 3A TFS39 3A TFS44 3A TFS49 3A SIDE WALL with 4 opening for...

Страница 6: ...ent parts and accessories as listed in these parts lists Before beginning installation be sure the burner system is complete by comparing its contents with this Parts List Parts may differ depending u...

Страница 7: ...illustrations in this manual are for general reference only Do not scale drawings Actual design elements will vary from case to case Pay attention to specified minimum clearances to combustibles WARNI...

Страница 8: ...accessories Use of other controls parts and accessories which are not designed for use with Burntech gas fireplaces is prohibited and will void all warranties certifications listings and building code...

Страница 9: ...t reading these procedures will save you time and at the most it will prevent any malfunction that could result in property damage or serious injury Do not start the installation until you have checke...

Страница 10: ...he addition of floor joists to align with the anchor brackets allows the brackets to be directly connected to the floor joists Note that additional floor joists may be required to support the weight o...

Страница 11: ...at time of installation and used under dry conditions the deflection resulting from L 0 5D is permitted to be substituted for the deflection resulting from L D Note that Burntech cannot accept respons...

Страница 12: ...washers GBVS 44 49 Eight 8 pieces 3 8 rebar x 36 long included with unit Eight 8 ea All thread x 12 long with nuts and washers ALL UNITS Three 3 90 lb bags of ready mix concrete with 1 4 or smaller ag...

Страница 13: ...latness level if necessary Figure 13 1 2 away from edges 1 2 mortar bead typical Hearth section shown prepared for Right Side position Apply mortar bead to all mating surfaces Apply mortar to the rema...

Страница 14: ...veled face lines up with the inward angles of the lintel sides Resulting top surfaces should be level Figure 20 Lower Dome Sides Rating Plate faces inside Verify that the smoke dome side front and rea...

Страница 15: ...5 Fireplace Finishes Combustible Trim Clearances Mantel and Mantel Shelf Clearances As with any radiant heat fireplaces all Burntech Fireplaces must comply with building code safety clearances per uni...

Страница 16: ...in an accident or malfunction If instructions are not followed the warranty on the product will become null and void 3 1 2 3 4 5 Note that the most important aspect of the installation is the maintena...

Страница 17: ...1 One elbow begins the installation procedure and the second elbow is used to finish off each section In all likelihood a 30 degreeoffsetelbowwillprobablybethefirsthardwareusedoff the top of the ancho...

Страница 18: ...lination Multiple offsets are permitted if they do not exceed a 45 inclination The total lengths of the two offsets are not required to meet the 75 allowable rule Figure 2 Example 3 Shows a single off...

Страница 19: ...re scheduled to install the round top termination unit or any of the flashings or flues that will be exposed to outside weather conditions Venting terminals shall not be recessed into walls or siding...

Страница 20: ...ch sensor pointed toward the room out of the fireplace Use six 6 drywalls screws to fasten it in place on the front most part of the firebox ceiling as shown through the six 6 pre drilled holes Attach...

Страница 21: ...SOAPY WATER SOLUTION IF A LEAK IS DETECTED TIGHTEN CONNECTIONS AND TEST AGAIN NEVER USE AN OPEN FLAME TO CHECK FOR GAS LEAKS Insert a one way screw into the hole in the front of each bracket and tight...

Страница 22: ...d the heat chambers facing the back of the fireplace Figure 35 Place the front log on the grate in front of the top burner pipe with the flat down and the heat chambers toward the burner pipe and the...

Страница 23: ...the four 4 screws above and below the control panel face then pull the control panel out far enough to expose the test ports on the valve Figure 41 Unscrew the port marked IN part way and test CAUTION...

Страница 24: ...ts a Check with a millivolt meter Should be 250 millivolts or more b Pilot flame making a blowing sound b Pilot needs adjusting see Checking and Adjusting the Pilot on page 22 c Generator wire leads a...

Страница 25: ...ncrete slab The concrete strength and durability shall comply with Sections 1903 1904 and 1905 of the International Building Code IBC TABLE R402 2 MINIMUM SPECIFIED COMPRESSIVE STRENGTH OF CONCRETE MI...

Страница 26: ...ly b Lines defining areas are approximate only Local conditions may be more or less severe than indicated by region classification A severe classification is where weather conditions result in signifi...

Страница 27: ...ded at Burntech Fireplace Solutions s option Nothing in this warranty makes Burntech Fireplace Solutions or any affiliate thereof liable in any respect for any injury or damage to the building or stru...

Отзывы: