background image

1

Contents

 ..........................................................................................................................................Pg. 1

Fireplace Parts List ..........................................................................................................................Pg. 2, 3

Burner and Logs Parts List ..............................................................................................................Pg. 4 

Product Overview ............................................................................................................................Pg. 5, 6

Clearance To Combustibles .............................................................................................................Pg. 7

Burntech® Fireplace & Chimney Systems.......................................................................................Pg. 7

Chimney System Heights ................................................................................................................Pg. 7

Supporting Floor Systems

 ...............................................................................................................Pg. 8, 9

What You Will Need .........................................................................................................................Pg. 10

Fireplace Assembly Procedures ......................................................................................................Pg. 11, 12

Burntech® Firebrick Liner ................................................................................................................Pg. 13

Installing Outside Air ........................................................................................................................Pg. 14

Burntech® Chimney Systems ..........................................................................................................Pg. 14

Determining Finished Height for Fireplace ......................................................................................Pg. 14, 15

Installing Vent Plate and Chimney Systems ....................................................................................Pg. 15

Venting Installation

 ...........................................................................................................................Pg. 16

Specifying Chimney Heights ............................................................................................................Pg. 17

Chimney Termination Units ..............................................................................................................Pg. 17

Important Pre-installation Information ..............................................................................................Pg. 17

Installing the Valve/Control Box Assembly .......................................................................................Pg. 18

Install Spill Switch and Baffle Assembly ..........................................................................................Pg. 18

Owner’s Operation & Precautions ...................................................................................................Pg. 18, 19

Attaching the Burner and Grate .......................................................................................................Pg. 19

Checking and Adjusting the Pilot .....................................................................................................Pg. 19

Placing the Decorative Lava Rock ...................................................................................................Pg. 19

Adjusting Air Mixers .........................................................................................................................Pg. 19

Log Placement .................................................................................................................................Pg. 20

Lighting and Operating Instructions .................................................................................................Pg. 21

Maintenance and Service ................................................................................................................Pg. 22

Troubleshooting

 ...............................................................................................................................Pg. 22

Appendix I ........................................................................................................................................Pg. 23

Appendix II .......................................................................................................................................Pg. 24

Warranty

 ..........................................................................................................................................Pg. 25

CONTENTS

Your fireplace must have a rating plate like the sample shown below and should be located inside the lower dome side of your fireplace. 

Model Number, Date of Manufacture and Serial Number should be stamped on the plate where indicated.

NG

LP

7. HOLES: 4X Ø 0.14” THRU

6. CLEAR BOXES NEXT TO MODEL NUMBERS ARE TO BE STAMPED DURING MANUFACTURE OF FIREPLACE.

5. LARGE TEXT TO BOLD UPPERCASE ARIAL, 10 PT. MIN. (WHERE SHOWN).

4. SMALLEST TEXT TO BE ARIAL, 8 PT. MIN (WHERE SHOWN).

3. ALL TEXT AND GRAPHICS TO BE BLACK ON A CONTRASTING, CLEAR ALUMINUM BACKGROUND.

2. FINISH: CLEAR, PROTECTIVE COATING AT RATED TEMPERATURE IN NOTE 1.

1. MATERIAL:  CLASS IIIA , .024 THICK ALUMINUM RATED AT 302°F (150°C).

NOTES

: UNLESS OTHERWISE SPECIFIED

File Name: GBV Series Burntech Rating Plate 11-19-2012.ai

REV: B

DATE: 11/19/12

LAST MODIFIED BY: CB

4.25”

4.00”

6.5”

6.25”

.12”

MFG. DATE:

SERIAL No.

This appliance is not for installation in manufactured or mobile homes.

    rev 19 NOV 2012

GAS

TYPE:

DO NOT REMOVE THIS LABEL

See Burntech Installation & Operating Instructions for 

this model. Contact local building officials about 

restrictions and  installation specifications in your area.

THIS FIREPLACE IS DESIGNED 

FOR USE ONLY WITH THE ANSI 

Z21.50 DECORATIVE GAS LOGS 

AND BURNER TESTED AND 

APPROVED FOR THIS FIREPLACE.

Consult instructions included with this 

firebox for further information.

!

WARNING:

Use only approved, listed chimneys

10” B-Type Vent and DM-12-10” 

system

(1) BFMP525 (included)

(1) GBV-DH10 (included)

Chimney Heights:

Max.: 40 ft.

Min.: 14 ft. (17 ft. with 1 or 2 offset 

sections maximum)

IMPORTANT: Refer to pipe 

manufacturer’s instructions.

!

WARNING:

THIS FIREPLACE HAS  BEEN TESTED 

FOR USE ONLY WITH APPROVED  

GLASS DOORS. TO REDUCE THE 

RISK OF FIRE OR INJURY, CONSULT 

OWNER’S MANUAL.

THIS APPLIANCE NEEDS FRESH AIR FOR SAFE OPERATION AND MUST BE INSTALLED 

SO THERE ARE PROVISIONS FOR ADEQUATE COMBUSTION AND VENTILATION AIR.

!

WARNING:

  THIS FIREPLACE IS NOT INTENDED FOR BURNING SOLID FUELS.

!

WARNING:

This gas appliance must not be connected to a chimney fuel servicing a solid fuel burning appliance.

!

FIREPLACE CLEARANCES TO COMBUSTIBLES:

UNIT FRONT, SIDES, REAR.......................................

0”

TOP..............................................................................

0”

VENT...................................................................1” (25.4 mm)

FRONT..............................................................48” (1219 mm)

PERPENDICULAR WALLS................................8” (203 mm)

FLOOR.........................................................................0”

CEILING............................................................24“ (610 mm)

MANTLE..............................................................3”  (76 mm)

INSULATION FROM FIREBOX...................................0”

The installation, including provisions for combustion, ventilation air, and required minimum permanent vent opening,

must conform with the National Fuel Gas Code (ANSI Z223.1/NFPA 54) and applicable local building codes.

MODEL

  No.:

GBVS39

GBVS44

GBVS49

6520 Platt Ave. #577

West Hills, CA 91307

Report

No. 08-154

ICC Evaluation 

Services Report 

No. 2401

PFS

®

US

EXAMPLE ONL

Y

Содержание GBVS 39/44/49

Страница 1: ...0 standard Solid fuels shall not be burned in this fireplace This appliance must be vented vertically through the roof This appliance is not for installation in manufactured or mobile homes The instal...

Страница 2: ...THIS PAGE INTENTIONALLY LEFT BLANK...

Страница 3: ...YPE DO NOT REMOVE THIS LABEL See Burntech Installation Operating Instructions for this model Contact local building officials about restrictions and installation specifications in your area THIS FIREP...

Страница 4: ...ponents Warning Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this appliance may result in property damage or personal injury...

Страница 5: ...DESCRIPTION QTY 1 TFS39 1 TFS44 1 TFS49 1 HEARTH Left or Right 2 2 TFS39 2 TFS44 2 TFS49 2 REAR WALL 3 3 TFS39 3 TFS44 3 TFS49 3 SIDE WALL 7 3A TFS39 3A TFS44 3A TFS49 3A SIDE WALL with 4 opening for...

Страница 6: ...ent parts and accessories as listed in these parts lists Before beginning installation be sure the burner system is complete by comparing its contents with this Parts List Parts may differ depending u...

Страница 7: ...illustrations in this manual are for general reference only Do not scale drawings Actual design elements will vary from case to case Pay attention to specified minimum clearances to combustibles WARNI...

Страница 8: ...accessories Use of other controls parts and accessories which are not designed for use with Burntech gas fireplaces is prohibited and will void all warranties certifications listings and building code...

Страница 9: ...t reading these procedures will save you time and at the most it will prevent any malfunction that could result in property damage or serious injury Do not start the installation until you have checke...

Страница 10: ...he addition of floor joists to align with the anchor brackets allows the brackets to be directly connected to the floor joists Note that additional floor joists may be required to support the weight o...

Страница 11: ...at time of installation and used under dry conditions the deflection resulting from L 0 5D is permitted to be substituted for the deflection resulting from L D Note that Burntech cannot accept respons...

Страница 12: ...washers GBVS 44 49 Eight 8 pieces 3 8 rebar x 36 long included with unit Eight 8 ea All thread x 12 long with nuts and washers ALL UNITS Three 3 90 lb bags of ready mix concrete with 1 4 or smaller ag...

Страница 13: ...latness level if necessary Figure 13 1 2 away from edges 1 2 mortar bead typical Hearth section shown prepared for Right Side position Apply mortar bead to all mating surfaces Apply mortar to the rema...

Страница 14: ...veled face lines up with the inward angles of the lintel sides Resulting top surfaces should be level Figure 20 Lower Dome Sides Rating Plate faces inside Verify that the smoke dome side front and rea...

Страница 15: ...5 Fireplace Finishes Combustible Trim Clearances Mantel and Mantel Shelf Clearances As with any radiant heat fireplaces all Burntech Fireplaces must comply with building code safety clearances per uni...

Страница 16: ...in an accident or malfunction If instructions are not followed the warranty on the product will become null and void 3 1 2 3 4 5 Note that the most important aspect of the installation is the maintena...

Страница 17: ...1 One elbow begins the installation procedure and the second elbow is used to finish off each section In all likelihood a 30 degreeoffsetelbowwillprobablybethefirsthardwareusedoff the top of the ancho...

Страница 18: ...lination Multiple offsets are permitted if they do not exceed a 45 inclination The total lengths of the two offsets are not required to meet the 75 allowable rule Figure 2 Example 3 Shows a single off...

Страница 19: ...re scheduled to install the round top termination unit or any of the flashings or flues that will be exposed to outside weather conditions Venting terminals shall not be recessed into walls or siding...

Страница 20: ...ch sensor pointed toward the room out of the fireplace Use six 6 drywalls screws to fasten it in place on the front most part of the firebox ceiling as shown through the six 6 pre drilled holes Attach...

Страница 21: ...SOAPY WATER SOLUTION IF A LEAK IS DETECTED TIGHTEN CONNECTIONS AND TEST AGAIN NEVER USE AN OPEN FLAME TO CHECK FOR GAS LEAKS Insert a one way screw into the hole in the front of each bracket and tight...

Страница 22: ...d the heat chambers facing the back of the fireplace Figure 35 Place the front log on the grate in front of the top burner pipe with the flat down and the heat chambers toward the burner pipe and the...

Страница 23: ...the four 4 screws above and below the control panel face then pull the control panel out far enough to expose the test ports on the valve Figure 41 Unscrew the port marked IN part way and test CAUTION...

Страница 24: ...ts a Check with a millivolt meter Should be 250 millivolts or more b Pilot flame making a blowing sound b Pilot needs adjusting see Checking and Adjusting the Pilot on page 22 c Generator wire leads a...

Страница 25: ...ncrete slab The concrete strength and durability shall comply with Sections 1903 1904 and 1905 of the International Building Code IBC TABLE R402 2 MINIMUM SPECIFIED COMPRESSIVE STRENGTH OF CONCRETE MI...

Страница 26: ...ly b Lines defining areas are approximate only Local conditions may be more or less severe than indicated by region classification A severe classification is where weather conditions result in signifi...