Contents
..........................................................................................................................................Pg. 1
Fireplace Parts List ..........................................................................................................................Pg. 2, 3
Burner and Logs Parts List ..............................................................................................................Pg. 4
Product Overview ............................................................................................................................Pg. 5, 6
Clearance To Combustibles .............................................................................................................Pg. 7
Burntech® Fireplace & Chimney Systems.......................................................................................Pg. 7
Chimney System Heights ................................................................................................................Pg. 7
Supporting Floor Systems
...............................................................................................................Pg. 8, 9
What You Will Need .........................................................................................................................Pg. 10
Fireplace Assembly Procedures ......................................................................................................Pg. 11, 12
Burntech® Firebrick Liner ................................................................................................................Pg. 13
Installing Outside Air ........................................................................................................................Pg. 14
Burntech® Chimney Systems ..........................................................................................................Pg. 14
Determining Finished Height for Fireplace ......................................................................................Pg. 14, 15
Installing Vent Plate and Chimney Systems ....................................................................................Pg. 15
Venting Installation
...........................................................................................................................Pg. 16
Specifying Chimney Heights ............................................................................................................Pg. 17
Chimney Termination Units ..............................................................................................................Pg. 17
Important Pre-installation Information ..............................................................................................Pg. 17
Installing the Valve/Control Box Assembly .......................................................................................Pg. 18
Install Spill Switch and Baffle Assembly ..........................................................................................Pg. 18
Owner’s Operation & Precautions ...................................................................................................Pg. 18, 19
Attaching the Burner and Grate .......................................................................................................Pg. 19
Checking and Adjusting the Pilot .....................................................................................................Pg. 19
Placing the Decorative Lava Rock ...................................................................................................Pg. 19
Adjusting Air Mixers .........................................................................................................................Pg. 19
Log Placement .................................................................................................................................Pg. 20
Lighting and Operating Instructions .................................................................................................Pg. 21
Maintenance and Service ................................................................................................................Pg. 22
Troubleshooting
...............................................................................................................................Pg. 22
Appendix I ........................................................................................................................................Pg. 23
Appendix II .......................................................................................................................................Pg. 24
Warranty
..........................................................................................................................................Pg. 25
CONTENTS
Your fireplace must have a rating plate like the sample shown below and should be located inside the lower dome side of your fireplace.
Model Number, Date of Manufacture and Serial Number should be stamped on the plate where indicated.
NG
LP
7. HOLES: 4X Ø 0.14” THRU
6. CLEAR BOXES NEXT TO MODEL NUMBERS ARE TO BE STAMPED DURING MANUFACTURE OF FIREPLACE.
5. LARGE TEXT TO BOLD UPPERCASE ARIAL, 10 PT. MIN. (WHERE SHOWN).
4. SMALLEST TEXT TO BE ARIAL, 8 PT. MIN (WHERE SHOWN).
3. ALL TEXT AND GRAPHICS TO BE BLACK ON A CONTRASTING, CLEAR ALUMINUM BACKGROUND.
2. FINISH: CLEAR, PROTECTIVE COATING AT RATED TEMPERATURE IN NOTE 1.
1. MATERIAL: CLASS IIIA , .024 THICK ALUMINUM RATED AT 302°F (150°C).
NOTES
: UNLESS OTHERWISE SPECIFIED
File Name: GBV Series Burntech Rating Plate 11-19-2012.ai
REV: B
DATE: 11/19/12
LAST MODIFIED BY: CB
4.25”
4.00”
6.5”
6.25”
.12”
MFG. DATE:
SERIAL No.
This appliance is not for installation in manufactured or mobile homes.
rev 19 NOV 2012
GAS
TYPE:
DO NOT REMOVE THIS LABEL
See Burntech Installation & Operating Instructions for
this model. Contact local building officials about
restrictions and installation specifications in your area.
THIS FIREPLACE IS DESIGNED
FOR USE ONLY WITH THE ANSI
Z21.50 DECORATIVE GAS LOGS
AND BURNER TESTED AND
APPROVED FOR THIS FIREPLACE.
Consult instructions included with this
firebox for further information.
!
WARNING:
Use only approved, listed chimneys
10” B-Type Vent and DM-12-10”
system
(1) BFMP525 (included)
(1) GBV-DH10 (included)
Chimney Heights:
Max.: 40 ft.
Min.: 14 ft. (17 ft. with 1 or 2 offset
sections maximum)
IMPORTANT: Refer to pipe
manufacturer’s instructions.
!
WARNING:
THIS FIREPLACE HAS BEEN TESTED
FOR USE ONLY WITH APPROVED
GLASS DOORS. TO REDUCE THE
RISK OF FIRE OR INJURY, CONSULT
OWNER’S MANUAL.
THIS APPLIANCE NEEDS FRESH AIR FOR SAFE OPERATION AND MUST BE INSTALLED
SO THERE ARE PROVISIONS FOR ADEQUATE COMBUSTION AND VENTILATION AIR.
!
WARNING:
THIS FIREPLACE IS NOT INTENDED FOR BURNING SOLID FUELS.
!
WARNING:
This gas appliance must not be connected to a chimney fuel servicing a solid fuel burning appliance.
!
FIREPLACE CLEARANCES TO COMBUSTIBLES:
UNIT FRONT, SIDES, REAR.......................................
0”
TOP..............................................................................
0”
VENT...................................................................1” (25.4 mm)
FRONT..............................................................48” (1219 mm)
PERPENDICULAR WALLS................................8” (203 mm)
FLOOR.........................................................................0”
CEILING............................................................24“ (610 mm)
MANTLE..............................................................3” (76 mm)
INSULATION FROM FIREBOX...................................0”
The installation, including provisions for combustion, ventilation air, and required minimum permanent vent opening,
must conform with the National Fuel Gas Code (ANSI Z223.1/NFPA 54) and applicable local building codes.
MODEL
No.:
GBVS39
GBVS44
GBVS49
6520 Platt Ave. #577
West Hills, CA 91307
Report
No. 08-154
ICC Evaluation
Services Report
No. 2401
PFS
®
US
EXAMPLE ONL
Y
Содержание GBVS 39/44/49