- 18 -
10.
PARTS LIST
Part
Part No
Front Ceramic Coal
COA4241F
Rear Ceramic Coal
COA4241B
Glass
GLA4140
Grill
GRI4240
90mm Freestanding Spacer
SPACERKIT
Remote Valve (Mertik)
Remote Handset
USE ONLY GENUINE REPLACEMENT PARTS.
Parts ordered from our factory will normally take 5 – 7 working days to be delivered.
An ‘Express service’ is available upon request.
Due to our policy of continual improvement and development the exact accuracy of descriptions
and illustrations cannot be guaranteed.
Burley Appliances are the only company to bench run and thoroughly test every single Flueless
gas fire it produces. Burley is in the unique position of knowing that every appliance leaves the
factory in perfect working order.
CLEANING AND MAINTENANCE
Ensure the appliance is switched off and cooled down before cleaning. The case and surround are
best cleaned with a damp cloth and wiped dry to avoid smearing. The glass is a special high
temperature ceramic material, if possible clean with a damp cloth, for more stubborn stains use a
ceramic hob cleaner such as hob-brite and polish off all traces. Spray waxes and polishes that
leave a residue, or abrasive cleaners must not be used.
The inside of the glass and fuel effects should need only infrequent cleaning. To do this, lift the
case off its clips and place to one side. Remove the 4 nuts and washers holding the glass clips in
place and put safe. Carefully remove the fuel effects, remembering how they fit in place and clean
around the burner area and fuel effects with a HEPA filtered vacuum with brush attachment. Using
the relevant section from the installers’ manual refit the fuel effects, glass and case.
On no account should the fire be used with glass removed. The fuel effects must not be replaced
in a different position from the instructions, if they are broken replace immediately. Do not use
additional or non standard fuel effects as to do so could cause a hazard.
If the fire is equipped with a remote control then check and change the batteries as described in
previously.
The fire should also be serviced annually by a competent person: Gas Safe ™ registered installer
(formerly CORGI) in the UK. This is best done before the heating season.
Содержание G4237/8 Image