background image

Installation and Operating Instructions

INVAUKP572     Issue 0

Panel Heaters

Dimensions

(millimetres)

Fig. 1

Fig. 2

Model

(

s

)

 

Watts 

PH 075                             

 750 

620 

108

PH 125 

 1250 

688 

108

PH 150 

1500 

688 

108

PH 200 

2000 

860 

108

PH 075T 

750 

620 

108

PH 125T 

1250 

688 

108

PH 150T 

1500 

688 

108

PH 200T 

2000 

860 

108

IMPORTANT : THESE INSTRUCTIONS SHOULD BE READ CAREFULLY AND RETAINED FOR FUTURE REFERENCE

Important Safety Advice 

When using electrical appliances, basic precautions should always 

be followed to reduce the risk of fire, electrical shock, and injury 

to persons, including the following:
IMPORTANT – The wall brackets supplied with the appliance must 

be used.
IMPORTANT – If the heater is installed in a room containing a bath 

or shower, it must be so installed that switches and other controls 

cannot be touched by a person using a bath or shower.
Do not use outdoors.
Do not locate the heater immediately below a fixed socket outlet 

or connection box.
Do not cover the heater. Do not place material or garments on 

the heater, or obstruct the air circulation around the heater, for 

instance by curtains or pushing furniture up against the heater, 

as this could cause overheating and a fire risk.
NEVER cover or obstruct in any way the heat outlet slots at the top 

of the heater or the air inlet slots in the base of the heater.
WARNING  –  THE  SURFACES  OF  THIS  HEATER  CAN  BE  HOT. 

Momentary contact with any part of the heater should not cause 

injury. However, aged or infirm persons or young children should 

not be left unsupervised in the vicinity of the heater unless a 

suitable guard is fitted.
This appliance is not intended for use by children or other persons 

without assistance or supervision if their physical, sensory or 

mental capabilities prevent them from using it safely. Children 

should be supervised to ensure that they do not play with the 

appliance. 
Note that due care and consideration must be taken when using 

this heater in series with a thermal control, a program controller, a 

timer or any other device that switches on the heat automatically, 

since a fire risk exists when the heater is accidentally covered or 

displaced.
If  the  supply  cord  is  damaged  it  must  be  replaced  by  the 

manufacturer or service agent or a similarly qualified person in 

order to avoid a hazard.

WARNING: IN ORDER TO AVOID OVERHEATING, DO NOT 

COVER THE HEATER.

Electrical

WARNING – THIS APPLIANCE MUST BE EARTHED 

The electrical installation must be carried out by a competent electrician, 

and be in strict accordance with the current I.E.E. regulations for Electrical 

Equipment in Buildings.

The heater is fitted with a length of flexible cable type H05VV-F size 3 x 

1.0mm

 on 0.75kW - 2.0kW models and size 3 x 1.5mm2 on 3.0kW

 

models, 

for connection to the fixed wiring of the premises through a suitable 

connection box positioned adjacent to the heater.

The supply circuit to the heater must incorporate a double pole isolating 

switch having a contact separation of at least 3mm.

Supplementary Earth Bonding

Should Equipotential Earth Bonding be required the earthing conductor 

in the supply cord is deemed to provide the supplementary bonding 

connection (see the 17

th

 Edition of the I.E.E. Wiring Regulations). 

General

The

 Panel heater is designed for wall mounting on the wall brackets 

supplied. It should only be operated when in the upright position as 

shown.

All models are splash proof to IP24 standard.

PH.... T  models are fitted with a 24 hour programme timer.

Before connecting the

 heater check that the supply voltage is the same 

as that stated on the heater.

Wall Mounting

IMPORTANT

 – The wall brackets supplied with the appliance must be 

used. The heater should be positioned observing the minimum clearances 

stated around the heater - see 

Fig. 1

.

DO NOT

 locate the heater immediately below a fixed socket outlet or 

connection box.
1.      Remove  wall  mounting  bracket  from  the  back  of  the                                                                                                                                              

            heater  by  depressing  the  spring  latch  at  the  top  of  each                                                                                                                                             

           bracket - see 

Fig. 2

.

2.        Fix the wall bracket securely to the wall through the four    

           screw holes provided.

3.        Present  the  heater  to  the  wall  bracket,  and  engage  lower                                                                                                                                            

           slots in the back with bracket.

4.        Raise  the  heater  to  upright  position  and  push  the  heater                                                                                                                                           

           onto brackets to engage top latch.

Access to the controls

To open the hinged controls cover, insert the blade of a screwdriver in 

the small slot on the right hand side of the cover, and gently lever the 

screwdriver outwards. On the 3kW model the controls are located on the 

top right hand corner, but the operations and functions are the same 

as the other models.  Note: After adjustment of the controls the control 

cover must be closed.

255

MIN

A

150
MIN

150
MIN

150
MIN

B

430

Отзывы: