background image

12 

4

 

If the unit continues to extinguish after a period of use, do not use it and seek the advice of 
your installer. 

5

 

Make sure that your installer has filled out your extended guarantee card and shown you how 
the fire operates. 

 

Cleaning the fuel effects 

The fuels can be accessed by opening the hinged door on the appliance which is secured by a 10mm 
nut.  On no account should the appliance be operated whilst the door is open. 
Do not lay the logs in any way other than that shown in the Installation and Servicing Instructions. 
 

Do not use the fire with broken logs. 
Do not add any additional fuel elements to the fire. 
Do not use similar looking parts from other appliances, use only genuine spare parts. 
Do not use the appliance for burning waste. 
The fire must not be run with the door open or with cracked, incorrectly fitted or missing glass. 
On no account must air inlets under the stove or outlet grills (see diagram) be obstructed.

 

 

 

TURN OFF PROCEDURE 

 

To  extinguish  the  pilot,  turn  the  valve  to  the  OFF position.  Note  that  if  the  gas  supply  fails  at  any 
time,  the  pilot  will  extinguish.  Leave  for  one  minute  then  carry  out  the  lighting  procedure  to  re-
ignite. 

GENERAL 

 

1.

 

To qualify for your free second year guarantee, you must fully complete and return the 
separate Guarantee Card. There are sections that your fitter must complete whilst he is fitting 
the fire. If the fully completed Guarantee Card is not returned within 7 days of fitting, the 
appliance is just covered by the standard 12 month guarantee. 

2.

 

As with all gas appliances, this fire MUST be serviced at least every 12 months, preferably at 
the start of the heating season. The second year guarantee is conditional on this service 
taking place. Servicing must be carried out by a qualified service engineer. 

 
BURLEY  APPLIANCES  ARE  THE  ONLY  COMPANY  TO  BENCH  RUN  AND  THOROUGHLY  TEST  EVERY 
SINGLE GAS FIRE IT PRODUCES. BURLEY ARE IN THE UNIQUE POSITION OF KNOWING THAT EVERY 
APPLIANCE LEAVES THE FACTORY IN PERFECT WORKING ORDER.

 

 

540 

620 

330 

Outlet grille 

DO NOT COVER 

Air inlets 

DO NOT BLOCK 

Содержание G4121 mk2

Страница 1: ...THE USER Burley Appliances Ltd Lands End Way Oakham Rutland LE15 6RB Telephone 44 0 1572 756956 Fax 44 0 1572 724390 e mail info burley co uk web www burley co uk G4121InstUser G20 31 Issue JAN08 v 1...

Страница 2: ...t High 3 5kW 3 5kW 250g h Low 1 7kW 1 7kW 120g h Inlet Connection 8mm Compression 8mm Compression Injector stereo 185 stereo 95 The inlet pressure must be within 1mBar of specification with all gas ap...

Страница 3: ...cubic feet by 35 3 Adjoining spaces not separated by a door may be combined 3 7 The heater must not be used on or against a combustible surface 3 8 No furniture soft furnishings decorations wall cove...

Страница 4: ...t for servicing 4 5 The surfaces of the appliance become very hot during use 4 6 Before cleaning or maintenance switch fire OFF and allow to cool 4 7 Any purpose provided ventilation should be checked...

Страница 5: ...etc All gas work should be undertaken by a competent person see General Requirements 8 Siting the Appliance 8 1 If the appliance is to be in or in front of an open fireplace the chimney or flue MUST b...

Страница 6: ...rner and the front log is pushed to the extreme left hand side as shown Take the 2 loose logs and position them as shown onto the cut outs on the base log taking care to locate them correctly to ensur...

Страница 7: ...f it does not light repeat the operation a few times Continue to hold knob for 15 20 sec s to establish the pilot and then release If pilot fails to establish turn off wait 1 minute then repeat lighti...

Страница 8: ...Protective clothing is not required but normal hygiene rules of no smoking eating or drinking in the work area should be followed Controls The system for monitoring the oxygen supply to the burner is...

Страница 9: ...IN THE UNIQUE POSITION OF KNOWING THAT EVERY APPLIANCE LEAVES THE FACTORY IN PERFECT WORKING ORDER Due to our policy of continual improvement and development the exact accuracy of descriptions and il...

Страница 10: ...956 Do not use any other type of paint GENERAL REQUIREMENTS 1 The heater is intended as a secondary heat source Check that a primary source of heat such as radiators is present in the room If insuffic...

Страница 11: ...e the fire purely as a heater in which case they will select a flame height then set the thermostat to a comfort level In both cases if the room gets too hot the thermostat will reduce the fire to pil...

Страница 12: ...obstructed TURN OFF PROCEDURE To extinguish the pilot turn the valve to the OFF position Note that if the gas supply fails at any time the pilot will extinguish Leave for one minute then carry out the...