background image

11 

material when hot. A propriety non-abrasive ceramic hob cleaner such as ‘hob brite’ can be used to 
clean the glass. 

9. When the heater is not used for a time, ensure the gas control or adjacent isolator is turned off. 

The heater is not to be used for a time, ensure the gas control or adjacent isolator is turned off. 

10. The heater must not be used in rooms where the atmosphere is likely to contain water or 
chemical vapours, which may adversely affect the appliance or its finish. 

11. Do not use whilst painting & decorating, or in newly decorated rooms as the residue can lead to 
unpleasant smells from the appliance. Always cover or have the appliance removed when 
decorating. 

 

CONTROLS 

The  fire  is  fitted  with  a  gas  valve  and  a  thermostat.  The  thermostat  automatically  regulates  the 
room temperature by turning the heat output (flames) up or down between high, half or pilot only. 

The thermostat bulb must be resited to a cool area to measure the air temperature in the room 

more accurately.

 See installation instructions or consult the manufacturer. 

 

LIGHTING PROCEDURE 

Make sure there is no smell of gas 

1.

 

Open the lower cover to reveal the gas control. 

2.

 

There are 2 control knobs on the appliance. The left hand one (coloured red) controls On / Off 

and  High  /  Low  flame.  The  right  hand  one  (coloured black)  is  the  comfort  level  thermostat  which 
turns  the  fire  to  pilot  position  once  the  desired  temperature  is  reached.  Some  people  prefer  to 
retain a flame effect using the left hand knob to control its height whilst keeping the thermostat set 
on hot. Others prefer to use the fire purely as a heater in which case they will select a flame height 
then set the thermostat to a comfort level. In both cases if the room gets too hot, the thermostat 
will reduce the fire to pilot setting. If during use the pilot is alight but the main burner will not light, 
check the thermostat position and if necessary select a warmer setting.  

3.

 

To  light  the  fire,  press  the  left  hand  (red)  control  knob  for  several  seconds  then  turn 

anticlockwise  to  the  ignition  position.  A  click  will  be  heard  and  the  pilot  (under  right  side  of  fuel 
bed) should light. If it does not repeat the operation a few times. Continue to hold knob for 15 – 20 
sec's to establish the pilot and then release. If pilot  fails to establish, turn off,  wait 1 minute then 
repeat  the  lighting  procedure.  Rotate  the  control  knob  to  high  flame  to  light  then  back  to  the 
desired flame position. If no gas comes through rotate the right knob (thermostat) to a hotter room 
setting and the fire will light.  

4.

 

Control the fire by a combination of thermostat and / or flame setting to suit your mode of use  

5.

 

To turn the fire off, rotate the left hand knob fully clockwise. 

 

NOTES

 

1

 

The  first  time  that  the  appliance  is  used,  there  will  be  some  odour  produced  due  to  the 
newness  of  the  materials.  It  is  recommended  that  the  unit  is  fired  at  maximum  setting  for 
several  hours  and  the  room  is  kept  ventilated  during  this  period.  It  is  usual  for  flueless 
appliances to produce an initial odour after start up. 

2

 

When  the  pilot  flame  is  alight,  the  unit  may  be  controlled  by  turning  the  knob  anywhere 
between  1  and  7.  If  the  pilot  flame  should  ever  extinguish  of  its  own  accord,  ventilate  the 
room and allow a minimum of 5 minutes before relighting.  

3

 

Never attempt to relight the unit if there is a gas smell. 

Содержание G4121 mk2

Страница 1: ...THE USER Burley Appliances Ltd Lands End Way Oakham Rutland LE15 6RB Telephone 44 0 1572 756956 Fax 44 0 1572 724390 e mail info burley co uk web www burley co uk G4121InstUser G20 31 Issue JAN08 v 1...

Страница 2: ...t High 3 5kW 3 5kW 250g h Low 1 7kW 1 7kW 120g h Inlet Connection 8mm Compression 8mm Compression Injector stereo 185 stereo 95 The inlet pressure must be within 1mBar of specification with all gas ap...

Страница 3: ...cubic feet by 35 3 Adjoining spaces not separated by a door may be combined 3 7 The heater must not be used on or against a combustible surface 3 8 No furniture soft furnishings decorations wall cove...

Страница 4: ...t for servicing 4 5 The surfaces of the appliance become very hot during use 4 6 Before cleaning or maintenance switch fire OFF and allow to cool 4 7 Any purpose provided ventilation should be checked...

Страница 5: ...etc All gas work should be undertaken by a competent person see General Requirements 8 Siting the Appliance 8 1 If the appliance is to be in or in front of an open fireplace the chimney or flue MUST b...

Страница 6: ...rner and the front log is pushed to the extreme left hand side as shown Take the 2 loose logs and position them as shown onto the cut outs on the base log taking care to locate them correctly to ensur...

Страница 7: ...f it does not light repeat the operation a few times Continue to hold knob for 15 20 sec s to establish the pilot and then release If pilot fails to establish turn off wait 1 minute then repeat lighti...

Страница 8: ...Protective clothing is not required but normal hygiene rules of no smoking eating or drinking in the work area should be followed Controls The system for monitoring the oxygen supply to the burner is...

Страница 9: ...IN THE UNIQUE POSITION OF KNOWING THAT EVERY APPLIANCE LEAVES THE FACTORY IN PERFECT WORKING ORDER Due to our policy of continual improvement and development the exact accuracy of descriptions and il...

Страница 10: ...956 Do not use any other type of paint GENERAL REQUIREMENTS 1 The heater is intended as a secondary heat source Check that a primary source of heat such as radiators is present in the room If insuffic...

Страница 11: ...e the fire purely as a heater in which case they will select a flame height then set the thermostat to a comfort level In both cases if the room gets too hot the thermostat will reduce the fire to pil...

Страница 12: ...obstructed TURN OFF PROCEDURE To extinguish the pilot turn the valve to the OFF position Note that if the gas supply fails at any time the pilot will extinguish Leave for one minute then carry out the...

Отзывы: